𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Simplified cool on-column injection with wide-bore capillaries

✍ Scribed by McCullough, Ph. R. ;Pacholec, F.


Publisher
John Wiley and Sons
Year
1985
Tongue
English
Weight
148 KB
Volume
8
Category
Article
ISSN
0935-6304

No coin nor oath required. For personal study only.


πŸ“œ SIMILAR VOLUMES


On-column injection on capillary columns
✍ Rinderknecht, F. ;Wenger, B. πŸ“‚ Article πŸ“… 1981 πŸ› John Wiley and Sons 🌐 English βš– 146 KB

negative chemical ionization spectra of TCDDs [12]. Conversely, no mechanism similarto the formation of a dichlorobenzoquinone anion of TCDD [lo] was detected for the three TCDF isomers. Also, no molecular anion was observed for any of the TCDF isomers investigated.

Analysis of headspace samples using off-
✍ Haynes, L. V. ;Steimle, A. R. πŸ“‚ Article πŸ“… 1987 πŸ› John Wiley and Sons 🌐 English βš– 421 KB πŸ‘ 1 views

Gas chromatographic equipment and procedures are described for automated splitless injection of pseudo-static headspace samples collected externally onto a sorbent trap. The GC microprocessor controls, in sequence, carrier gas backflushing of the sorbent trap for water removal, splitless thermal des

Separation of mixtures of solvents with
✍ Gerbino, Tomaso C. ;Castello, Gianrico πŸ“‚ Article πŸ“… 1992 πŸ› John Wiley and Sons 🌐 English βš– 537 KB

## Abstract The gas chromatographic separation of the components of a complex mixture of industrial solvents, not possible on a single stationary phase owing to coelution of some of the compounds, has been achieved on two serially connected wide bore capillary columns of different polarity. The an

Gas chromatography of plasma amino acids
✍ Labadarios, D. ;Moodie, I. M. ;Burger, J. A. ;Shephard, G. S. πŸ“‚ Article πŸ“… 1988 πŸ› John Wiley and Sons 🌐 English βš– 351 KB πŸ‘ 1 views

A procedure is described in which a wide bore glass capillary column is used as an alternative to the more traditional packed column in the analysis of amino acid levels in plasma. The coefficientsof variationforallaminoacids (with theexceptionof aspartic acid) were better than 1 1 O h with recoveri

Underivatized steroids on persilanized c
✍ Kovarich, E. ;Munari, F. πŸ“‚ Article πŸ“… 1982 πŸ› John Wiley and Sons 🌐 English βš– 381 KB

## Abstract Recent developments in the preparation of capillary columns by persilanization of the glass surfaces have resulted in highly inactive, heat‐stable columns. With this type of column certain steroid hormone classes can be analyzed without derivatization; these include the 17‐keto steroids