𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Simple and rapid flow-injection spectrophotometric determination of carbaryl after liquid-liquid extraction

✍ Scribed by Karim D. Khalaf; A. Morales-Rubio; M. de la Guardia


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
696 KB
Volume
280
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A simple procedure was developed for the spectrophotometric determination of carbaryl and its hydrolysis product I-naphthol in water. These compounds are extracted into xylene and back-extracted, as the 1-naphtholate, with 0.2 M NaOH. A 600-~1 volume of the alkaline extract is injected into a flow analysis manifold which provides the reaction between naphtholate and 50 pg ml-' p-aminophenol solution in the presence of 0.004 M KIO, and spectrophotometric measurement is carried out at 5% nm. The method provides a limit of detection of 26.5 ng ml-' carbaryl and a sample frequency of 110 injections per hour. Recoveries in different types of matrices vary from 95 to 102%.


πŸ“œ SIMILAR VOLUMES


Flow-injection method for the determinat
✍ Shoji Motomizu; Masanori Kobayashi πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 449 KB

Anromc surfactants m water samples were determmed by a spectrophotometrlc and a spectrofluorlmetrlc method mvohng flow mjectlon coupled with hqmd-hquld extractlon On-tube detection wlthout any phase separators was adopted by usmg a glass capdlaIy flow cell (Inner diameter 0 8 mm) Two kmds of dyes we

Spectrofluorimetric determination of ber
✍ Tadao Sakai; Noriko Ohno; Yong Soon Chung; Harumitu Nishikawa πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 348 KB

A sensitive and rapid determination of berberine was carried out by flow-injection analysis. Berberine was successfully extracted in the presence of sodium perchlorate. The calibration graph was linear over the range 4 X 10d9-1 X 1O-6 mol dm-". The sample throughput was 42 h-l.

Spectrophotometric determination of tota
✍ Wolfgang Frenzel; Stephanie Krekler πŸ“‚ Article πŸ“… 1995 πŸ› Elsevier Science 🌐 English βš– 882 KB

Flow injection ailalysis (FIA) procedures for the spectrophotometric determination of phenol involving m-line concentration by solvent and sorbent extraction have been developed. The imine product formed in the reaction between phenol and 4-aminoantipyrine (6AAP) is either extracted into chloroform

Flow-injection in-valve solid-phase extr
✍ Kate Grudpan; Jaroon Jakmunee; Ponlayuth Sooksamiti πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 202 KB πŸ‘ 2 views

Flow-injection analysis (FIA) system incorporating in-valve solid-phase extraction microcolumn for on-line separation and preconcentration using a new resin, U/TEVA.Spec, has been proposed for the spectrophotometric determination of uranium in geological samples using 4-(2-pyridylazo) resorcinol (PA

Flow injection, amperometric determinati
✍ Zuliang Chen; Ji Jin Yu; D. Brynn Hibbert πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 302 KB

Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly