Anromc surfactants m water samples were determmed by a spectrophotometrlc and a spectrofluorlmetrlc method mvohng flow mjectlon coupled with hqmd-hquld extractlon On-tube detection wlthout any phase separators was adopted by usmg a glass capdlaIy flow cell (Inner diameter 0 8 mm) Two kmds of dyes we
Simple and rapid flow-injection spectrophotometric determination of carbaryl after liquid-liquid extraction
β Scribed by Karim D. Khalaf; A. Morales-Rubio; M. de la Guardia
- Publisher
- Elsevier Science
- Year
- 1993
- Tongue
- English
- Weight
- 696 KB
- Volume
- 280
- Category
- Article
- ISSN
- 0003-2670
No coin nor oath required. For personal study only.
β¦ Synopsis
A simple procedure was developed for the spectrophotometric determination of carbaryl and its hydrolysis product I-naphthol in water. These compounds are extracted into xylene and back-extracted, as the 1-naphtholate, with 0.2 M NaOH. A 600-~1 volume of the alkaline extract is injected into a flow analysis manifold which provides the reaction between naphtholate and 50 pg ml-' p-aminophenol solution in the presence of 0.004 M KIO, and spectrophotometric measurement is carried out at 5% nm. The method provides a limit of detection of 26.5 ng ml-' carbaryl and a sample frequency of 110 injections per hour. Recoveries in different types of matrices vary from 95 to 102%.
π SIMILAR VOLUMES
A sensitive and rapid determination of berberine was carried out by flow-injection analysis. Berberine was successfully extracted in the presence of sodium perchlorate. The calibration graph was linear over the range 4 X 10d9-1 X 1O-6 mol dm-". The sample throughput was 42 h-l.
Flow injection ailalysis (FIA) procedures for the spectrophotometric determination of phenol involving m-line concentration by solvent and sorbent extraction have been developed. The imine product formed in the reaction between phenol and 4-aminoantipyrine (6AAP) is either extracted into chloroform
Flow-injection analysis (FIA) system incorporating in-valve solid-phase extraction microcolumn for on-line separation and preconcentration using a new resin, U/TEVA.Spec, has been proposed for the spectrophotometric determination of uranium in geological samples using 4-(2-pyridylazo) resorcinol (PA
Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly