𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Spectrophotometric determination of total phenolics by solvent extraction and sorbent extraction optosensing using flow injection methodology

✍ Scribed by Wolfgang Frenzel; Stephanie Krekler


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
882 KB
Volume
310
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Flow injection ailalysis (FIA) procedures for the spectrophotometric determination of phenol involving m-line concentration by solvent and sorbent extraction have been developed. The imine product formed in the reaction between phenol and 4-aminoantipyrine (6AAP) is either extracted into chloroform (solvent extraction) or is temporarily retained on C,,-modified silica material contained in a microcolumn (sorbent extraction). In the latter case two variants of detection have been used namely the spectrophotometric measurement of the methanolic eluent containing the concentrated dye and at-column optosensing of the retained reaction product followed by methanol elution to maintain reversibility of the process. In the solvent extraction procedure a lo-fold increase of sensitivity compared to the common FIA method without extraction is achieved but no corresponding improvement in detectability is observed. Under optimized conditions the detection limit amounts to 8 pg 1-l. Using sorbent extraction methodology, high concentration factors can be obtained when large sample volumes are used. The only limitation in getting correspondingly lower detection limits are an increasingly high and variable blank value with sampling volume. The detection limits obtained for measurement of the absorbance in the eluent and on-column optosensing are 11 /*g 1-l and 0.4 pg l-', respectively. A study of the extractability of various phenol derivates using both solvent and sorbent extraction revealed lower relative response rates compared to the FL4 method without extraction. Phenolics that possess an additional acidic group are present in ionized form at the high pH of the assay and are not extractable at all.


πŸ“œ SIMILAR VOLUMES


Flow-injection analysis determination of
✍ EncarnaciΓ³n RodrΓ­guez Gonzalo; JosΓ© Luis PΓ©rez PavΓ³n; Jaromir Ruzicka; Gary D. C πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 703 KB

The determmatlon of phenohc compounds m kerosene by flow-mjectlon analysis has been mvestlgated The approach IS based on the reactlon of phenols urlth 4-ammoanttpyrme m the presence of an oxldlzmg agent to form red compounds easdy detectable at 500 nm Phenohcs are separated from kerosene through a s

Direct automatic determination of bitter
✍ J.A. GarΓ­a-Mesa; M.D. Luque de Castro; M. ValcΓ‘rcel πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 633 KB

An automated version of an exlstmg batch method for the determmatlon of blttemess m wgm olive 011 was developed The automatic method 1s based on flow-mjection analysis @IA) prmclples and 1s Implemented by couphng an FIA mamfold to a sohd-bqmd retention unit m which the sample matm IS retamed on a C,

Selective flow injection sorbent extract
✍ Renli Ma; Willy Van Mol; Freddy Adams πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 964 KB

A flow injection sorbent extraction system was developed for determination of trace and ultratrace cadmium, copper and lead in biological and environmental standard reference materials by graphite furnace atomic absorption spectrometty (GFAAS). Using ammonium diethyldithiophosphate (DDPA) as complex

Determination of Cd, Co, Cu, Mn, Ni, Pb,
✍ A. Bortoli; M. Gerotto; M. Marchiori; F. Mariconti; M. Palonta; A. Troncon πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 98 KB

The concentrations of Cd, Co, Cu, Mn, Ni, Pb, and Zn in natural and sea waters are too low to be directly determined with by flame atomic absorption spectrometry (FAAS) or graphite furnace atomic absorption spectrometry (GFAAS). Specific sample preparations are requested that make possible the deter