๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Selective flow injection sorbent extraction for determination of cadmium, copper and lead in biological and environmental samples by graphite furnace atomic absorption spectrometry

โœ Scribed by Renli Ma; Willy Van Mol; Freddy Adams


Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
964 KB
Volume
293
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


A flow injection sorbent extraction system was developed for determination of trace and ultratrace cadmium, copper and lead in biological and environmental standard reference materials by graphite furnace atomic absorption spectrometty (GFAAS). Using ammonium diethyldithiophosphate (DDPA) as complexing agent with citrate as masking agent at pH 2, the analytes were selectively preconcentrated with effective removal of the matrixes including the salt matrix in saline water and the other high-content heavy metals in digested biological and geological samples. The two-second eluate containing most of the analyte complexes was collected for the GFAAS measurement. All analytical results obtained were in good agreement with the certified values. Enrichment factors of 12, 13 and 13 compared with 20 ~1 direct injection of aqueous solution and detection limits (3~) of 0.003,0.05 and 0.04 pg I-' for cadmium, copper and lead respectively, could be obtained with 20-s sample loading at 8.7 ml min-' for sorbent extraction and 20 ~1 eluate injection for peak area measurement. The relative standard deviation at 0.1 pg 1-l cadmium, 1 pg 1-l copper or 3 pg 1-l lead was around 2%.


๐Ÿ“œ SIMILAR VOLUMES


Determination of cadmium, copper and lea
โœ Renli Ma; Willy Van Mol; Freddy Adams ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 998 KB

A flow injection on-line sorbent extraction system was studied in conjunction with flame atomic absorption spectrometry to determine cadmium, copper and lead in digest solutions of solid environmental samples using octadecyl functional groups (C,,) bonded silica gel as sorbent with diethylammonium-Z

Time-based and volume-based sampling for
โœ Bernhard Welz; Xuefeng Yin; Michael Sperling ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 945 KB

Flow-mJectlon on-hne preconcentratlon systems for graphite furnace atomic absorptton spectrometry are comphcated by the low eluate volume of typtcally less than 50 ~1 which can be accommodated m a graphtte tube or on a graphite platform Even when a column wtth an extra small capactty of 15 ~1 was us

Determination of Ultratrace Amounts of C
โœ M.H. Wang; A.I. Yuzefovsky; R.G. Michel ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 827 KB

Methods are described for the determination of ultratrace amounts of copper and cadmium in seawater by graphite furnace atomic absorption spectrometry with flow-injection, microcolumn preconcentration. A new type of \(\mathrm{C}_{18}\) column loaded with sodium diethyldithiocarbamate (sodium-DDC) wa

Determination of traces of copper, cadmi
โœ Pei-Ling Lu; Kuang-Shie Huang; Shiuh-Jen Jiang ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 620 KB

Plow-injection isotope dilution inductively coupled plasma mass spcctrometry (RIP-MS) was applied to the determination of Cu, Cd and Pb in several biological and environmental reference materials. The isotope ratios for each injection were calculated from the areas of the flow-jnjection peaks. The p

Determination of arsenic and selenium in
โœ Chris C.Y. Chan; Ram S. Sadana ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 571 KB

Flow-injection analysis is applied to sample introduction in conjunction with automated hydride generation and AAS for the determination of As and Se in environmental samples such as soil, vegetation, waters, sediments, and industrial wastes. A large sample loop was used to provide high sensitivitie