𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Rapid quantitative measurements of proteomes by Fourier transform ion cyclotron resonance mass spectrometry

✍ Scribed by Richard D. Smith; Ljiljana Paša-Tolić; Mary S. Lipton; Pamela K. Jensen; Gordon A. Anderson; Yufeng Shen; Thomas P. Conrads; Harold R. Udseth; Richard Harkewicz; Mikhail E. Belov; Christophe Masselon; Timothy D. Veenstra


Publisher
John Wiley and Sons
Year
2001
Tongue
English
Weight
303 KB
Volume
22
Category
Article
ISSN
0173-0835

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


252Cf plasma desorption fourier transfor
✍ S. K. Viswanadham; D. M. Hercules; R. R. Weller; C. S. Giam 📂 Article 📅 1987 🏛 John Wiley and Sons 🌐 English ⚖ 205 KB 👁 1 views

The ions produced by "'Cf plasma desorption are detected by Fourier transform ion cyclotron resonance techniques. Results for CsI and N,N,N-trimethyl-p-aminophenolate iodide show the feasibility of the technique with high resolution (up to 11 000 at m / z 23) and good signal-to-noise ratio (up to 72

Advantages of High Magnetic Field for Fo
✍ Alan G. Marshall; Shenheng Guan 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 488 KB 👁 2 views

It is well-known that mass resolving power in Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) can increase linearly with increasing applied magnetic field induction, B. Here, we show that eight other FTICR primary performance parameters theoretically also increase linearly (qu

Electrospray ionisation Fourier-transfor
✍ Sally-Ann Poulsen; Paul J. Gates; Graham R. L. Cousins; Jeremy K. M. Sanders 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 97 KB 👁 2 views

The use of electrospray ionisation Fourier-transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) for the analysis of dynamic combinatorial libraries (DCLs) of pseudo-peptide macrocyclic hydrazone oligomers is presented. The design of library building blocks results in mixtures

Fourier Transform Ion Cyclotron Resonanc
✍ Christopher L. Hendrickson; Jared J. Drader; David A. Laude; Shenheng Guan; Alan 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 378 KB 👁 2 views

We present Fourier transform ion cyclotron resonance (FTICR) mass spectra at a magnetic field of 20 T; more than twice the highest field previously used for FTICR. Our instrument is based on a resistive magnet installed at the National High Magnetic Field Laboratory. The magnet has a 50mm diameter b

Generation of hydrogen radicals for reac
✍ Plamen A. Demirev 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 69 KB 👁 1 views

An efficient technique for generation of H\* (D\*) radicals in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is described. The method allows the probing of the reactivity of gas-phase H\* radicals towards various ions isolated in the cell of an FTICR mass spectrometer. Results

Positive-ion Electrospray–Fourier Transf
✍ Meiyu He; Jiaxi Xu; Tak Wah Dominic Chan; Rebecca L. C. Lau 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 343 KB 👁 2 views

We have determined the mas spectra of three polypeptides which have been designed as an effective reagent to be used in the diagnosis of a Chinese strain of Hepatitis E Virus (HEV). The spectra were determined by elecbrospwy ionization-Fourier transform ion cyclotron resonance mass spectrometer. The