We present Fourier transform ion cyclotron resonance (FTICR) mass spectra at a magnetic field of 20 T; more than twice the highest field previously used for FTICR. Our instrument is based on a resistive magnet installed at the National High Magnetic Field Laboratory. The magnet has a 50mm diameter b
Advantages of High Magnetic Field for Fourier Transform Ion Cyclotron Resonance Mass Spectrometry
β Scribed by Alan G. Marshall; Shenheng Guan
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 488 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
It is well-known that mass resolving power in Fourier transform ion cyclotron resonance mass spectrometry (FTICR MS) can increase linearly with increasing applied magnetic field induction, B. Here, we show that eight other FTICR primary performance parameters theoretically also increase linearly (quadrupolar axialization efficiency, data acquisition speed), quadratically (upper mass limit, maximum ion kinetic energy, maximum number of trapped ions, maximum ion trapping duration, two-dimensional FTICR mass resolving power), or inverse-quadratically (peak coalescence tendency) with increasing B. The origin of (and conditions for) the magnetic field dependence of each of these parameters are presented and discussed. These fundamental advantages lead to corollary improvement in other FTICR performance parameters: e.g. signal-to-noise ratio, dynamic range, mass accuracy, ion remeasurement efficiency and mass selectivity for MS/MS. Finally, we note that these various advantages may be exploited in combination, so as to produce even higher enhancement in a particular parameter: e.g. signal-to-noise ratio can improve by more than a factor of Bz if mass resolving power is fixed at the same value as at lower magnetic field.
π SIMILAR VOLUMES
The use of electrospray ionisation Fourier-transform ion cyclotron resonance tandem mass spectrometry (ESI-FTICR-MS/MS) for the analysis of dynamic combinatorial libraries (DCLs) of pseudo-peptide macrocyclic hydrazone oligomers is presented. The design of library building blocks results in mixtures
An efficient technique for generation of H\* (D\*) radicals in Fourier transform ion cyclotron resonance (FTICR) mass spectrometry is described. The method allows the probing of the reactivity of gas-phase H\* radicals towards various ions isolated in the cell of an FTICR mass spectrometer. Results
We have determined the mas spectra of three polypeptides which have been designed as an effective reagent to be used in the diagnosis of a Chinese strain of Hepatitis E Virus (HEV). The spectra were determined by elecbrospwy ionization-Fourier transform ion cyclotron resonance mass spectrometer. The