𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitative Bioanalysis Utilizing High-performance Liquid Chromatography/Electrospray Mass Spectrometry via Selected-ion Monitoring of the Sodium Ion Adduct [M + NNa]+

✍ Scribed by Mohammed Jemal; Robert B. Almond; Debbie S. Teitz


Publisher
John Wiley and Sons
Year
1997
Tongue
English
Weight
143 KB
Volume
11
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A high-performance liquid chromatography (HPLC)/electrospray mass spectrometric method for quantitative determination of a compound in dog plasma was developed and validated via the selected-ion monitoring of the electrospray-generated [M + Na] + adduct of the compound. The plasma samples were acidified with HCl and then extracted with methyl tert-butyl ether. The reconstituted extracts were injected into an HPLC/positive-ion electrospray ionization mass spectrometry system. The HPLC mobile phase consisted of acetonitrile, water, formic acid (3 mM) and sodium acetate (0.3 mM). This composition of mobile phase provided the optimum electrospray condition for the formation of the [M + Na] + -ion. This work demonstrates that the addition of sodium acetate into the HPLC mobile phase and the subsequent selected-ion monitoring of the sodium ion adduct of the analyte is a viable approach in quantitative bioanalysis. The facile formation of the sodium ion adduct of the analyte, which does not contain functional groups that are known to be strong proton acceptors, appears to be a function of the particular electrospray instrument used.


πŸ“œ SIMILAR VOLUMES


Evaluation of high performance liquid ch
✍ Pierre-HervΓ© Lambert; Jean A. Boutin; Sophie Bertin; Jean-Luc FauchΓ¨re; Jean-Pau πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 132 KB πŸ‘ 2 views

Liquid chromatography/electrospray mass spectrometry with selected-ion monitoring makes possible the visualization and positive identification of a family of isobaric ions from libraries comprising hundreds of peptides. For larger libraries (up to 10 5 peptides), a given peptide, known to be unique

The use of high-flow high performance li
✍ M. Jemal; Yuan-Qing; Daisy B. Whigan πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 210 KB πŸ‘ 1 views

Two bioanalytical methods have been developed and validated utilizing high flow high performance liquid chromatography (HPLC) for on-line purification of plasma and serum samples and electrospray tandem mass spectrometry for detection and quantitation. Each plasma or serum sample, after mixing with

Positive ion electrospray ionization tan
✍ Robert L. St. Claire III πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 107 KB πŸ‘ 1 views

A novel analytical procedure has been developed for the analysis of intracellular nucleotide triphosphates. Positive ion electrospray ionization tandem mass spectrometry (MS/MS) was interfaced to ion-pairing highperformance liquid chromatography (HPLC) utilizing a mobile phase containing 10 mM ammon

Quantitative Analysis of Mevinolinic Aci
✍ R. E. Calaf; M. Carrascal; E. GelpΓ­; J. Abian πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 136 KB πŸ‘ 2 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and

High performance liquid chromatography m
✍ Mohammed Jemal; Zheng Ouyang; Deborah S. Teitz πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 100 KB πŸ‘ 2 views

A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T