The use of high-flow high performance liquid chromatography coupled with positive and negative ion electrospray tandem mass spectrometry for quantitative bioanalysis via direct injection of the plasma/serum samples

✍ Scribed by M. Jemal; Yuan-Qing; Daisy B. Whigan


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
210 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


Two bioanalytical methods have been developed and validated utilizing high flow high performance liquid chromatography (HPLC) for on-line purification of plasma and serum samples and electrospray tandem mass spectrometry for detection and quantitation. Each plasma or serum sample, after mixing with an aqueous solution of the internal standard, was injected into a small diameter (1 Γ‚ 50 mm) column packed with large particles of OASIS (30 mm), with a 100% aqueous mobile phase at a high flow rate (3-4 mL/min). The combination of the high linear speed (6-8 cm/s) of the aqueous mobile phase and the large particle size resulted in the rapid passage of the proteins and other large biomolecules through the column while the small-molecule analytes were retained on the column. During this purification period, the HPLC effluent was directed to waste. After the purification step, the HPLC mobile phase was rapidly changed from 100% aqueous to 100% organic, the flow was reduced to 0.5-0.8 mL/min, and the column effluent was directed towards the mass spectrometer. The small molecule analytes were eluted during this period. In the method developed and validated for the quantitative determination of compound I in rat plasma (method A), the same OASIS column (1 Γ‚ 50 mm, 30 mm) served as the purification and analytical (elution) column. In the method developed for the simultaneous determination of pravastatin and its positional isomer biotransformation product (SQ-31906) in human serum (method B), the purification column was connected to a conventional C18 analytical column (3.9 Γ‚ 50 mm, 5 mm) to achieve the required chromatographic separation between the two isomers. For method A, where 50 mL of rat plasma mixed 1:1 with water containing the internal standard was injected, the standard curve range was 1 to 1000 ng/mL. For method B, where 200 mL of a human serum sample mixed 4:1 with water containing the internal standard was injected, the standard curve range was 0.5 to 100 ng/mL. The total analysis time for each method was 5 min per sample. The accuracy, inter-day precision and intra-day precision were within 10% for both methods.


πŸ“œ SIMILAR VOLUMES


Quantitative Analysis of Mevinolinic Aci
✍ R. E. Calaf; M. Carrascal; E. GelpΓ­; J. Abian πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 136 KB πŸ‘ 2 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and

Positive ion electrospray ionization tan
✍ Robert L. St. Claire III πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 107 KB πŸ‘ 1 views

A novel analytical procedure has been developed for the analysis of intracellular nucleotide triphosphates. Positive ion electrospray ionization tandem mass spectrometry (MS/MS) was interfaced to ion-pairing highperformance liquid chromatography (HPLC) utilizing a mobile phase containing 10 mM ammon

High performance liquid chromatography m
✍ Mohammed Jemal; Zheng Ouyang; Deborah S. Teitz πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 100 KB πŸ‘ 2 views

A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T

A versatile system of high-flow high per
✍ Mohammed Jemal; Zheng Ouyang; Yuan-Qing Xia; Mark L Powell πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 144 KB

A bioanalytical method has been developed and validated for quantitation of a b-lactam drug candidate and its open-ring biotransformation product utilizing high-flow high-performance liquid chromatography (HPLC) for on-line purification of plasma samples and electrospray tandem mass spectrometry for