𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Positive ion electrospray ionization tandem mass spectrometry coupled to ion-pairing high-performance liquid chromatography with a phosphate buffer for the quantitative analysis of intracellular nucleotides

✍ Scribed by Robert L. St. Claire III


Publisher
John Wiley and Sons
Year
2000
Tongue
English
Weight
107 KB
Volume
14
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A novel analytical procedure has been developed for the analysis of intracellular nucleotide triphosphates. Positive ion electrospray ionization tandem mass spectrometry (MS/MS) was interfaced to ion-pairing highperformance liquid chromatography (HPLC) utilizing a mobile phase containing 10 mM ammonium phosphate, pH 6.4, with 2 mM tetrabutylammonium hydroxide and 15% acetonitrile. The methodology was developed to support the analysis of the 5'-triphosphate anabolite of the antiviral agent (Γ€)-FTC ((2R,5S)-5fluoro-1-[2-(hydroxymethyl-1,3-oxathiolan-5-yl]cytosine) in human peripheral blood mononuclear cells (PBMCs). In this procedure, all nucleotides were extracted from PBMCs with aqueous methanol, isolated with high recovery using a novel ion-pairing solid phase extraction procedure, and then analyzed directly with LC/MS/MS with a 10-min analysis time. A calibration curve was generated representing (Γ€)-FTC 5'triphosphate ((Γ€)-FTCTP) concentration over the range of 0.083 to 83 picomol/10 6 cells (approximately 0.08 to 80 picomoles on-column). Linear regression analysis with 1/x 2 weighting yielded a coefficient of determination (r 2 ) of greater than 0.999. The back-calculated concentrations of all calibration standards had relative errors within the range of 5 to Γ€3%. A preliminary assessment of intra-assay precision and accuracy, analyte stability, and LC/MS system stability indicated a robust method capable of being validated with a limit of quantitation estimated conservatively at 0.08 picomol/10 6 cells (approximately 0.08 picomoles on-column; signal-to-noise (S/N) = 5). The general method developed here should be adaptable to all purine-and pyrimidine-based nucleotide applications. This report provides a detailed discussion on the key HPLC, MS, and sample preparation procedures that hold the potential for even greater nucleotide sensitivity.


πŸ“œ SIMILAR VOLUMES


Quantitative Analysis of Mevinolinic Aci
✍ R. E. Calaf; M. Carrascal; E. GelpΓ­; J. Abian πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 136 KB πŸ‘ 1 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and

The use of high-flow high performance li
✍ M. Jemal; Yuan-Qing; Daisy B. Whigan πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 210 KB

Two bioanalytical methods have been developed and validated utilizing high flow high performance liquid chromatography (HPLC) for on-line purification of plasma and serum samples and electrospray tandem mass spectrometry for detection and quantitation. Each plasma or serum sample, after mixing with

High performance liquid chromatography m
✍ Mohammed Jemal; Zheng Ouyang; Deborah S. Teitz πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 100 KB πŸ‘ 1 views

A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. T

A simple liquid–liquid extraction with h
✍ Yuan-Qing Xia; Daisy B. Whigan; Mohammed Jemal πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 246 KB πŸ‘ 1 views

Four sensitive, specific and accurate methods, based on high-performance liquid chromatography (HPLC) with positive ion electrospray tandem mass spectrometry (MS/MS) coupled with liquid-liquid extraction (LLE), have been developed and validated for the low-picogram determination of two drug candidat

Evaluation of high performance liquid ch
✍ Pierre-HervΓ© Lambert; Jean A. Boutin; Sophie Bertin; Jean-Luc FauchΓ¨re; Jean-Pau πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 132 KB πŸ‘ 1 views

Liquid chromatography/electrospray mass spectrometry with selected-ion monitoring makes possible the visualization and positive identification of a family of isobaric ions from libraries comprising hundreds of peptides. For larger libraries (up to 10 5 peptides), a given peptide, known to be unique