๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

High performance liquid chromatography mobile phase composition optimization for the quantitative determination of a carboxylic acid compound in human plasma by negative ion electrospray high performance liquid chromatography tandem mass spectrometry

โœ Scribed by Mohammed Jemal; Zheng Ouyang; Deborah S. Teitz


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
100 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


A systematic investigation was undertaken to study the effects of varying concentrations of additives in the acetonitrile/water high performance liquid chromatography mobile phase, especially formic acid and ammonium formate, on the negative ion electrospray response of a carboxylic acid compound. The study showed that the response progressively decreased with increase in the formic acid concentration. While such a decrease in the response could be qualitatively explained by the decrease in the concentration of the ionized form of the carboxylic acid compound due to the lower pH of the mobile phase, the change in response was not as large as expected from the change of the concentration of the ionized form. The response also progressively decreased with increase in the ammonium formate concentration but the decrease cannot be explained by the change in the pH of the mobile phase. Although the best negative ion electrospray response was obtained with a water/acetonitrile mobile phase that contained no additives at all, the retention time of the analyte was not found to be adequately reproducible on repeated injections. Thus, this mobile phase was deemed unacceptable for practical, routine use. Comparing formic acid against ammonium formate, the former was preferable since it caused a smaller attenuation of the negative ion response. Equally important was the fact that addition of formic acid had the desirable effect of maintaining a reasonably high capacity factor (k') for the analyte even at a relatively high acetonitrile concentration. A concentration of 1 mM formic acid in the mobile phase was large enough to achieve the reproducible elongated retention time for the analyte, with a loss in the analyte response of about 60% only. It should be noted that the sensitivity achieved with the 1 mM formic acid mobile phase, in which the carboxylic acid is expected to be about 10% in the ionized form, is about 9 times better than the sensitivity achieved in the 1 mM ammonium formate mobile phase, in which the carboxylic acid is expected to be about 99% in the ionized form.


๐Ÿ“œ SIMILAR VOLUMES


Quantitative Analysis of Mevinolinic Aci
โœ R. E. Calaf; M. Carrascal; E. Gelpรญ; J. Abian ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 136 KB ๐Ÿ‘ 1 views

Mevinolinic acid (MVA), the major active metabolite of Lovastatin in human blood, is analysed by microbore high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Quantification is carried out by using methylmevinolinic acid (MMVA) as internal standard. Positive-and

Quantitative determination of E5880 in r
โœ Kikuchi, Kiyomi; Sano, Yoshihisa; Taniguchi, Sachie; Matsui, Kenji; Namiki, Masa ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 130 KB

A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity a

Quantitative determination of Ecteinasci
โœ Rosing, H.; Hillebrand, M. J. X.; Jimeno, J. M.; Gรณmez, A.; Floriano, P.; Faircl ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 124 KB ๐Ÿ‘ 1 views

A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced

High-performance liquid chromatography t
โœ Cristina Sottani; Claudio Minoia; Maurizio D'Incalci; Massimiliano Paganini; Mas ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 88 KB ๐Ÿ‘ 1 views

A sensitive, specific, accurate and reproducible analytical method was developed and validated for the quantitation of the anticancer agent paclitaxel in human plasma. This procedure is based on high performance liquid chromatography/ion spray -tandem mass spectrometry. This methodology is highly sp

A simple liquidโ€“liquid extraction with h
โœ Yuan-Qing Xia; Daisy B. Whigan; Mohammed Jemal ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 246 KB ๐Ÿ‘ 2 views

Four sensitive, specific and accurate methods, based on high-performance liquid chromatography (HPLC) with positive ion electrospray tandem mass spectrometry (MS/MS) coupled with liquid-liquid extraction (LLE), have been developed and validated for the low-picogram determination of two drug candidat

The use of high-flow high performance li
โœ M. Jemal; Yuan-Qing; Daisy B. Whigan ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 210 KB

Two bioanalytical methods have been developed and validated utilizing high flow high performance liquid chromatography (HPLC) for on-line purification of plasma and serum samples and electrospray tandem mass spectrometry for detection and quantitation. Each plasma or serum sample, after mixing with