𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitative determination of E5880 in rat plasma by high-performance liquid chromatography/electrospray ionization tandem mass spectrometry

✍ Scribed by Kikuchi, Kiyomi; Sano, Yoshihisa; Taniguchi, Sachie; Matsui, Kenji; Namiki, Masayuki; Ito, Hatsue; Sakurai, Hideki; Yoshimura, Tsutomu


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
130 KB
Volume
34
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


A simple and sensitive method is described for the determination of E5880 in rat plasma. The method is based on high-performance liquid chromatography/electrospray ionization mass spectrometry, using deuterated E5880 as an internal standard. Selected reaction monitoring is employed for selectivity and sensitivity, this in turn enables quantification in a short period of time (within 7 minutes) over the extended range of 0.1-1000 ng/ml with acceptable precision and accuracy. The method demonstrated to be suitable for the quantitative analysis of E5880 in rat plasma. The pharmacokinetic profile of E5880 after a single intravenous administration of E5880 was elucidated.


πŸ“œ SIMILAR VOLUMES


Quantitative determination of Ecteinasci
✍ Rosing, H.; Hillebrand, M. J. X.; Jimeno, J. M.; GΓ³mez, A.; Floriano, P.; Faircl πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 124 KB πŸ‘ 1 views

A method was developed for the bio-analysis of Ecteinascidin 743 (ET-743) using miniaturized liquid chromatography (LC) coupled to an electrospray ionization sample inlet (TurbolonSpray) and two quadrupole mass analyzers (LC/ESI-MS/MS). Solid-phase extraction was used as a sample pretreatment proced

Quantitative determination of ochratoxin
✍ Lau, B. P.-Y.; Scott, P. M.; Lewis, D. A.; Kanhere, S. R. πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 163 KB πŸ‘ 1 views

Mass spectrometry of ochratoxin A (OTA) and B (OTB) under electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) was studied. ESI offers higher sensitivities and less fragmentation than APCI. A sensitive LC/MS/MS method for the determination of ochratoxin A (OTA) in human

Quantitative determination of DNA adduct
✍ Siethoff, Christoph; Feldmann, Ingo; Jakubowski, Norbert; Linscheid, Michael πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 147 KB πŸ‘ 1 views

The quantitative determination of nucleotides from DNA modiÐed by styrene oxide is described using a combination of inductively coupled plasma high-resolution mass spectrometry (ICP-HRMS) and electrospray ionization mass spectrometry (ESI-MS), both interfaced to reversed-phase high-performance liqui

Molecular species of sphingomyelin: dete
✍ Karlsson, Anders Γ….; MichΓ©lsen, Peter; Odham, GΓΆran πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 144 KB πŸ‘ 1 views

In a sphingomyelin-enriched sample of polar lipids from bovine milk, molecular species of intact sphingomyelin were separated by normal-phase high-performance liquid chromatography and detected by mass spectrometry (MS) for structural information. First, by using electrospray with positive ionizatio

Electrospray ionization mass spectrometr
✍ Carlo Giorgio Zambonin; Francesco Palmisano πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 79 KB πŸ‘ 1 views

The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra