## Abstract ## Purpose To evaluate microvascular and relaxation parameters of prostate and nearby muscle in patients with benign prostatic hyperplasia (BPH), and to examine measurement reproducibility. ## Materials and Methods In this prospective study, 13 patients with BPH were imaged twice pri
Precision in measurements of perfusion and microvascular permeability with T1-weighted dynamic contrast-enhanced MRI
✍ Scribed by Lucy E. Kershaw; David L. Buckley
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 286 KB
- Volume
- 56
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because inaccurate estimates or neglect of BAT contribute to inaccuracy in model fitting. Furthermore, although the precision with which these parameters are estimated is very important, it is rarely reported. To address these issues, two investigations were undertaken. First, simulated data were used to validate an independent method for estimation of BAT. Second, the adiabatic approximation to the tissue homogeneity model was fitted to experimental data acquired in prostate and muscle tissue of 22 patients with prostate cancer. A bootstrap error analysis was performed to estimate the precision of parameter estimates. The independent method of estimating BAT was found to be more accurate and precise than a model‐fitting approach. Estimated precisions for parameters measured in the prostate gland were 14% for extraction fraction (median coefficient of variation), 19% for blood flow, 28% for permeability‐surface area product, 35% for volume of the extravascular‐extracellular space, and 36% for blood volume. Techniques to further reduce uncertainty are discussed. Magn Reson Med, 2006. © 2006 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To examine the sensitivity of quantitative dynamic contrast enhanced MRI (DCE‐MRI) perfusion maps to errors in the various source images and to determine optimal imaging parameters for reducing this sensitivity. ## Materials and Methods A detailed analysis of the precision
## Abstract Inflow effects were studied for __T__~1~‐weighted, fast gradient‐echo, contrast‐enhanced MRI. This was done on the basis of realistic simulations (e.g., taking slice profiles into account) for unsteady flow. The area under the point spread function (PSF) was used to estimate the flow‐re
## Abstract In recent years a number of physiological models have gained prominence in the analysis of dynamic contrast‐enhanced __T__~1~‐weighted MRI data. However, there remains little evidence to support their use in estimating the absolute values of tissue physiological parameters such as perfu
A multiparametric computer-aided diagnosis scheme that combines information from T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2-weighted MRI was investigated using a database of 110 malignant and 86 benign breast lesions. Automatic lesion segmentation was performed, and three categories of l