## Abstract Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because
Inflow correction of hepatic perfusion measurements using T1-weighted, fast gradient-echo, contrast-enhanced MRI
✍ Scribed by Frank Peeters; Laurence Annet; Laurent Hermoye; Bernard E. Van Beers
- Publisher
- John Wiley and Sons
- Year
- 2004
- Tongue
- English
- Weight
- 271 KB
- Volume
- 51
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Inflow effects were studied for T~1~‐weighted, fast gradient‐echo, contrast‐enhanced MRI. This was done on the basis of realistic simulations (e.g., taking slice profiles into account) for unsteady flow. The area under the point spread function (PSF) was used to estimate the flow‐related enhancement. A simple analytical model that accurately describes the inflow effects was derived and validated. This model was used to correct the experimental perfusion calibration curves (signal intensity vs. relaxation rate) for inflow effects. Hepatic perfusion measurements, performed on patients, were analyzed in terms of a dual‐input, first‐order linear model. It was shown that inflow causes incorrect perfusion input functions. The resulting estimated perfusion parameters displayed a systematic error of typically 30–40%. By performing two extra time‐resolved flow measurements during the examination, one can correct the input functions. Magn Reson Med 51:710–717, 2004. © 2004 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To compare the usefulness of short inversion recovery (STIR) and T1‐weighted, contrast‐enhanced, fat‐suppressed (T1W‐CEFS) sequences for the evaluation of bone tumors. ## Materials and Methods Eighteen patients with 19 bone tumors who underwent both STIR and T1W‐CEFS imagi
## Abstract ## Purpose To compare respiratory‐triggered T2‐weighted fast spin‐echo (RTT2W‐FSE) and gradient T2\*‐weighted recalled‐echo (T2\*W‐GRE) images for visualization of malignant hepatic tumors using ferucarbotran‐enhanced magnetic resonance (MR) imaging. ## Materials and Methods Ferucarb
## Abstract Breakdown of the blood‐brain barrier (BBB), occurring in many neurological diseases, has been difficult to measure noninvasively in humans. Dynamic contrast‐enhanced magnetic resonance imaging measures BBB permeability. However, important technical challenges remain and normative data f