𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI

✍ Scribed by David L. Buckley


Publisher
John Wiley and Sons
Year
2002
Tongue
English
Weight
202 KB
Volume
47
Category
Article
ISSN
0740-3194

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

In recent years a number of physiological models have gained prominence in the analysis of dynamic contrast‐enhanced T~1~‐weighted MRI data. However, there remains little evidence to support their use in estimating the absolute values of tissue physiological parameters such as perfusion, capillary permeability, and blood volume. In an attempt to address this issue, data were simulated using a distributed pathway model of tracer kinetics, and three published models were fitted to the resultant concentration‐time curves. Parameter estimates obtained from these fits were compared with the parameters used for the simulations. The results indicate that the use of commonly accepted models leads to systematic overestimation of the transfer constant, K^trans^, and potentially large underestimates of the blood plasma volume fraction, V~p~. In summary, proposals for a practical approach to physiological modeling using MRI data are outlined. Magn Reson Med 47:601–606, 2002. © 2002 Wiley‐Liss, Inc.


📜 SIMILAR VOLUMES


Combined use of T2-weighted MRI and T1-w
✍ Neha Bhooshan; Maryellen Giger; Li Lan; Hui Li; Angelica Marquez; Akiko Shimauch 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 490 KB 👁 1 views

A multiparametric computer-aided diagnosis scheme that combines information from T1-weighted dynamic contrast-enhanced (DCE)-MRI and T2-weighted MRI was investigated using a database of 110 malignant and 86 benign breast lesions. Automatic lesion segmentation was performed, and three categories of l

Precision in measurements of perfusion a
✍ Lucy E. Kershaw; David L. Buckley 📂 Article 📅 2006 🏛 John Wiley and Sons 🌐 English ⚖ 286 KB

## Abstract Dynamic contrast‐enhanced MRI is used to estimate microvascular parameters by tracer kinetics analysis. The time for the contrast agent to travel from the artery to the tissue of interest (bolus arrival time (BAT)) is an important parameter that must be measured in such studies because

Quantitative measurement of blood-brain
✍ Saeid Taheri; Charles Gasparovic; Nadim Jon Shah; Gary A. Rosenberg 📂 Article 📅 2010 🏛 John Wiley and Sons 🌐 English ⚖ 301 KB

## Abstract Breakdown of the blood‐brain barrier (BBB), occurring in many neurological diseases, has been difficult to measure noninvasively in humans. Dynamic contrast‐enhanced magnetic resonance imaging measures BBB permeability. However, important technical challenges remain and normative data f