𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Nonequilibrated sample manipulation—The essence of flow-injection analysis

✍ Scribed by Zhaolun Fang


Publisher
Elsevier Science
Year
1992
Tongue
English
Weight
477 KB
Volume
45
Category
Article
ISSN
0026-265X

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Automated injection of slurry samples in
✍ M. Hulsman; M. Bos; W.E. van der Linden 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 637 KB

Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed s

Aspects of sample dispersion for optimiz
✍ Takashi Korenaga 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 931 KB

Solute dispersion of an injected sample plug was studied by using an experimental apparatus with ideal lammar flow m order to develop a hydrodynamic model for the design of sensitwe and precise flow-injection analysis systems The dispersion behaviour of the sample slug under different manifold conch

Effect of chemical diffusivity on the pe
✍ Jinxin Li; Guojun Liu; Huichang Ma; Takashi Korenaga 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 590 KB

This paper deals with the difference in residence time of the two reagent/sample interface peaks produced in a single channel manifold. This difference in residence time is explained on the basis of a dispersion model, and the relevant factors were studied. It was found that in both sample injection

Effect of sample viscosity on the behavi
✍ Lars Risinger; Gillis Johansson 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 535 KB

VISCOUS samples unll cause pressure changes which affect the transfer of solutes through an on-lme dlalyzer Pressure changes can cause pre-peaks m the recorded slgnal due to membrane movements The flow-rate m the reuxver channel mcreases temporanly as the pressure budds up A pressure dtfferentml of

Flow injection analysis with amperometri
✍ M.Teresa Fernández-Abedul; A Costa-García 📂 Article 📅 1996 🏛 Elsevier Science 🌐 English ⚖ 441 KB

Flow injection analysis (FIA) with amperometric detection is applied to the determination of cocaine. Flow parameters were optimised prior to electrode calibration: a detection potential of +l V vs. Ag/AgCYsat. KC1 and a flow rate of 2.5 ml min-' resulted adequate. A relative standard deviation of 1

The second coming of flow-injection anal
✍ Jaromir Růžička 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 774 KB

The state of art of the flow-inJectIon techmque IS reviewed and Its future development IS outhned by emphaslzlng the importance of stopped-flow and sequential InJection methodologies and by dlscussmg common aspects of flow mJectlona6a chromatographlc techmques Keywords Flow System, Review