Automated injection of slurry samples in flow-injection analysis

✍ Scribed by M. Hulsman; M. Bos; W.E. van der Linden


Publisher
Elsevier Science
Year
1996
Tongue
English
Weight
637 KB
Volume
324
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


Two types of injectors are described for introducing solid samples as slurries in flow analysis systems. A time-based and a volume-based injector based on multitube solenoid pinch valves were built, both can be characterized as hydrodynamic injectors. Reproducibility of the injections of dispersed solids (< 150 pm) was tested with several concentrations of slurry samples up to 30 mg/ml; the injected volume was 1 ml. For both injectors dye and slurry samples could be injected with good precision (relative standard deviation for the peak area less than 2%). Peak detection was performed turbidimetrically. Data analysis and operation of the injectors were automated. The usual peristaltic pumps in flow analysis are normally not capable of handling slurries of the type investigated, therefore a valveless piston pump was used instead.


πŸ“œ SIMILAR VOLUMES


An automated system for multichannel flo
✍ U. Spohn; J. van der Pol; R. Eberhardt; B. Joksch; Ch. Wandrey πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 1022 KB

An automated multi-channel flow-injection analyzer was developed both for new flow-injection analysis (FIA) procedures and for the process monitoring of animal and microbial cultivations. Up to six different analytes can be determined sequentially. The FL4 set-up is working with up to six enzyme rea

Automated Determination of Antibody Oxid
✍ C.A.C. Wolfe; D.S. Hage πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 454 KB

The oxidation of antibody carbohydrate residues is a common approach used for site-specific antibody immobilization or modification. In this study a flow injection analysis system (FIA) was developed for monitoring antibody oxidation. Antibodies were oxidized with periodate and the resulting aldehyd

Flow injection analysis with amperometri
✍ M.Teresa FernΓ‘ndez-Abedul; A Costa-GarcΓ­a πŸ“‚ Article πŸ“… 1996 πŸ› Elsevier Science 🌐 English βš– 441 KB

Flow injection analysis (FIA) with amperometric detection is applied to the determination of cocaine. Flow parameters were optimised prior to electrode calibration: a detection potential of +l V vs. Ag/AgCYsat. KC1 and a flow rate of 2.5 ml min-' resulted adequate. A relative standard deviation of 1

Electroosmotically pumped capillary flow
✍ Shaorong Liu; Purnendu K. Dasgupta πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 602 KB

In flow-injection analysis (FJA) systems with electroosmotic flow (EOF), the maximum permissible sample throughput is a function of the electric field strength, capillary length and injection volume. The relation behveen the various parameters is theoretically and experimentally discussed. Experimen