๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Electroosmotically pumped capillary flow-injection analysis: Valve-based injection systems and sample throughput

โœ Scribed by Shaorong Liu; Purnendu K. Dasgupta


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
602 KB
Volume
283
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

โœฆ Synopsis


In flow-injection analysis (FJA) systems with electroosmotic flow (EOF), the maximum permissible sample throughput is a function of the electric field strength, capillary length and injection volume. The relation behveen the various parameters is theoretically and experimentally discussed. Experimental results are in reasonable agreement with theoretical expectations. The potential of EOF pumped FL4 using very short capillaries and relatively low applied voltages is discussed.


๐Ÿ“œ SIMILAR VOLUMES


Flow-injection analysis in the capillary
โœ Shaoring Liu; Purnendu K. Dasgupta ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 580 KB

## AbStlWt Electroosmotlc flow induced by an electric field m a 75Frn bore fused-silica capillary IS used as the pumping mechanism for flow-mJectlon analysis (FIA) InJection of a sample mto a reagent stream contammg a tamer electrolyte or sequential mJectlon of contiguous reagent, sample and reage

Electroosmotically pumped capillary form
โœ Shaorong Liu; Purnendu K. Dasgupta ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 392 KB

## An electroosmotically pumped capillary format sequential injection analysis system with a membrane sampling interface for determination of gaseous analytes is introduced. The applicability of the system has been demonstrated by the determination of ammonia at the parts per billion level. The ef

Enzyme-Based Flow Injection Analysis Sys
โœ Christian Mayer; Alexandra Frauer; Thomas Schalkhammer; Fritz Pittner ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 105 KB

We present the setup of a flow injection analysis system designed for on-line monitoring of glutamate and glutamine. These amino acids represent a major energy source in mammalian cell culture. A cycling assay consisting of glutamate dehydrogenase and aspartate aminotransferase produces NADH proport

Determination of dipyrone in pharmaceuti
โœ Juan A. Pradana Pรฉrez; Jesรบs S. Durand Alegrรญa; Pilar Fernรกndez Hernando; Adolfo ๐Ÿ“‚ Article ๐Ÿ“… 2011 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 805 KB

## ABSTRACT A rapid, economic and sensitive chemiluminescent method involving flowโ€injection analysis was developed for the determination of dipyrone in pharmaceutical preparations. The method is based on the chemiluminescent reaction between quinolinic hydrazide and hydrogen peroxide in a strongly