## Abstract In vivo ^31^P spectra were acquired from the human primary visual cortex at 7 T. The relaxation times of the cerebral metabolites, intracellular pH, rate constant (__k__~__f__~) of the creatine kinase (CK) reaction, and nuclear Overhauser enhancement (NOE) on the detected phosphorus moi
In vivo magnetic resonance elastography of human brain at 7 T and 1.5 T
✍ Scribed by Uwe Hamhaber; Dieter Klatt; Sebastian Papazoglou; Maurice Hollmann; Jörg Stadler; Ingolf Sack; Johannes Bernarding; Jürgen Braun
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 845 KB
- Volume
- 32
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose:
To investigate the feasibility of quantitative in vivo ultrahigh field magnetic resonance elastography (MRE) of the human brain in a broad range of low‐frequency mechanical vibrations.
Materials and Methods:
Mechanical vibrations were coupled into the brain of a healthy volunteer using a coil‐driven actuator that either oscillated harmonically at single frequencies between 25 and 62.5 Hz or performed a superimposed motion consisting of multiple harmonics. Using a motion sensitive single‐shot spin‐echo echo planar imaging sequence shear wave displacements in the brain were measured at 1.5 and 7 T in whole‐body MR scanners. Spatially averaged complex shear moduli were calculated applying Helmholtz inversion.
Results:
Viscoelastic properties of brain tissue could be reliably determined in vivo at 1.5 and 7 T using both single‐frequency and multifrequency wave excitation. The deduced dispersion of the complex modulus was consistent within different experimental settings of this study for the measured frequency range and agreed well with literature data.
Conclusion:
MRE of the human brain is feasible at 7 T. Superposition of multiple harmonics yields consistent results as compared to standard single‐frequency based MRE. As such, MRE is a system‐independent modality for measuring the complex shear modulus of in vivo human brain in a wide dynamic range. J. Magn. Reson. Imaging 2010;32:577–583. © 2010 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
As a noninvasive modality, MR is attractive for in vivo skin imaging. Its unique soft tissue contrast makes it an ideal imaging modality to study the skin water content and to resolve the different skin layers. In this work, the challenges of in vivo high-resolution skin imaging are addressed. Three
## Abstract The magnetic resonance absorption spectrum, __T__~1~ and __T__~2~ relaxation time distributions, and magnetization transfer properties of __ex vivo__ breast tissue have been characterized at 1.5 T and 37°C. The fraction of fibroglandular tissue within individual tissue samples (__n__ =
## Abstract In vivo ^1^H NMR spectra from the human brain were measured at 7 T. Ultrashort echo‐time STEAM was used to minimize J‐modulation and signal attenuation caused by the shorter __T__~2~ of metabolites. Precise adjustment of higher‐order shims, which was achieved with FASTMAP, was crucial t
The use of water suppression for in vivo proton MR spectroscopy diminishes the signal intensities from resonances that undergo magnetization exchange with water, particularly those downfield of water. To investigate these exchangeable resonances, an inversion transfer experiment was performed using