## Abstract ## Purpose To investigate the feasibility of 7T magnetic resonance imaging (MRI) to visualize and quantify trabecular bone structure in vivo by comparison with 3T MRI and in vivo three‐dimensional (3D) high‐resolution peripheral quantitative computed tomography (HR‐pQCT). ## Materials
In vivo high-resolution magnetic resonance skin imaging at 1.5 T and 3 T
✍ Scribed by Joëlle K. Barral; Neal K. Bangerter; Bob S. Hu; Dwight G. Nishimura
- Publisher
- John Wiley and Sons
- Year
- 2010
- Tongue
- English
- Weight
- 336 KB
- Volume
- 63
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
✦ Synopsis
As a noninvasive modality, MR is attractive for in vivo skin imaging. Its unique soft tissue contrast makes it an ideal imaging modality to study the skin water content and to resolve the different skin layers. In this work, the challenges of in vivo high-resolution skin imaging are addressed. Three 3D Cartesian sequences are customized to achieve high-resolution imaging and their respective performance is evaluated. The balanced steady-state free precession (bSSFP) and gradient echo (GRE) sequences are fast but can be sensitive to off-resonance artifacts. The fast large-angle spin echo (FLASE) sequence provides a sharp depiction of the hypodermis structures but results in more specific absorption rate (SAR). The effect of increasing the field strength is assessed. As compared to 1.5 T, signalto-noise ratio at 3 T slightly increases in the hypodermis and almost doubles in the dermis. The need for fat/water separation is acknowledged and a solution using an interleaved three-point Dixon method and an iterative reconstruction is shown to be effective. The effects of motion are analyzed and two techniques to prevent motion and correct for it are evaluated. Images with 117 × 117 × 500 µm 3 resolution are obtained in imaging times under 6 min. Magn Reson Med 63:790-796, 2010.
📜 SIMILAR VOLUMES
The role of high-resolution imaging has generally been discernible in the image. The use of this concept holds potential limited because of the associated loss of signal-to-noise ratio (SNR) for defining the appropriate imaging parameters to allow an object as voxel size decreases and imaging time i
## Abstract A 39‐year‐old female patient with thoracic syringomyelia underwent routine magnetic resonance imaging (MRI) and 3 T MRI to investigate the value of retrospectively cardiac‐gated cine steady‐state free precession (SSFP) MRI in the preoperative and postoperative diagnosis of arachnoid mem
## Abstract ## Purpose To evaluate the feasibility of MRI of the female pelvis using high‐resolution T2‐weighted imaging (T2WI) and the half‐Fourier acquisition single‐shot turbo spin‐echo (HASTE) technique at 3 Tesla (T) compared to 1.5T, while focusing on the uterine body and cervical anatomy.
## Abstract MRI can be used to investigate human skin microvasculature in vivo, provided adequate spatial resolution. Therefore, the sensitivity of the experiment has to be optimized to achieve sufficient signal‐to‐noise ratio (SNR) within reasonable measurement time to minimize motion artifacts, i