𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow injection-solid phase spectrofluorimetric determination of pyridoxine in presence of group B-vitamins

✍ Scribed by A. Ruiz-Medina; M. L. Fernández-de Córdova; A. Molina-Díaz


Book ID
105897519
Publisher
Springer
Year
1999
Tongue
English
Weight
82 KB
Volume
363
Category
Article
ISSN
1618-2650

No coin nor oath required. For personal study only.


📜 SIMILAR VOLUMES


Spectrofluorimetric flow injection deter
✍ A. Kojło; J.Martínez Calatayud 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 325 KB

A novel strategy for the preparation of solid-phase reactors by "impregnation" of a poly(vinyl chloride) coil with the reagent was carried out and applied to the fluorimetric flow injection determination of adrenaline. The calibration graph was linear over the range 5-2.5 mg 1-l of adrenaline, the r

Spectrofluorimetric determination of vit
✍ Mir Azam Khan; Seung Oh Jin; Sang Hak Lee; Hye Young Chung 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 233 KB 👁 1 views

## Abstract In this work a new spectrofluorimetric method for the determination of vitamin B~1~, based on the catalytic activity of horseradish peroxidase (HRP) in the presence of hydrogen peroxide (H~2~O~2~), has been developed. Non‐fluorescent vitamin B~1~ was easily converted through catalytic o

Flow-injection spectrofluorimetric deter
✍ N. Chimpalee; D. Chimpalee; B. Boonyanitchayakul; D.Thorburn Burns 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 292 KB

Boron can be determined spectrofluorimetrically based on the reaction of borate ion and Alizarin Red S in aqueous media using flow-injection analysis. The carrier stream was deionized water and the reagent streams were 1% (w/v) EDTA, phosphate buffer (pH 7.5) and 2 X lo-' M Alizarin Red S solutions.

Flow injection, amperometric determinati
✍ Zuliang Chen; Ji Jin Yu; D. Brynn Hibbert 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 302 KB

Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly

Flow-injection spectrophotometric determ
✍ Clezio Aniceto; Airton Vicente Pereira; Cícero Oliveira Costa-Neto; Orlando Fati 📂 Article 📅 1999 🏛 John Wiley and Sons 🌐 English ⚖ 151 KB 👁 2 views

06 50.0 mg L ‫1מ‬ (calibration graph: A ‫ס‬ ‫2310.0מ‬ ‫ם‬ 0.0134 C, r ‫ס‬ 0.9990, where A is the absorbance and C is the vitamin B 1 concentration in mg L ‫1מ‬ ). Sucrose, glucose, fructose, lactose, citric acid, starch, vitamin B 2 , and vitamin B 6 do not interfere, even in concentrations five tim