๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Flow-injection determination of 3-hydroxybutyrate in serum with an immobilized 3-hydroxybutyrate dehydrogenase reactor and fluorescence detection

โœ Scribed by Nobutoshi Kiba; Hidekazu Koemado; Motohisa Furusawa


Book ID
116069516
Publisher
Elsevier Science
Year
1994
Tongue
English
Weight
319 KB
Volume
41
Category
Article
ISSN
0039-9140

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Flow-injection determination of 3-hdroxy
โœ Nobutoshi Kiba; Hidekazu Koemado; Motoshisa Furusawa ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 414 KB

A flow-injection system for the determination of 3-hydroxybutyrate in serum is described. 3-Hydroxybutyrate dehydrogenase is immobilized on poly(vinyl alcohol) beads and incorporated in a flow-injection system. 1-Methoxy-Smethylphenazinium methylsulphate reacts with enzymatically generated NADH to g

Determination of 3-hydroxybutyrate in se
โœ Nobutoshi Kiba; Hidekazu Koemado; Junko Inagaki; Motohisa Furusawa ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 451 KB

A flow-injection system with a co-immobilized enzyme reactor is described for the determination of 3-hydroxybutyrate. 3-Hydroxybutyrate dehydrogenase and NADH oxidase were immobilized on aminated poly (vinyl alcohol) beads and packed into a stainless-steel column (5 cm X 4 mm i.d.). Serum was dilute

A Chemiluminescence-Flow Injection Analy
โœ M. Tabata; M. Totani ๐Ÿ“‚ Article ๐Ÿ“… 1995 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 433 KB

We describe a simple method for the highly sensitive chemiluminescence--flow injection analysis of 3-hydroxybutyrate in serum using a bioreactor column consisting of the two immobilized enzymes, 3-hydroxybutyrate dehydrogenase and NADH oxidase. The method was based on measuring the level of chemilum

Flow-injection determination of glucose
โœ Nobutoshi Kiba; Fumito Ueda; Motohisa Furusawa; Takeshi Yamane ๐Ÿ“‚ Article ๐Ÿ“… 1992 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 386 KB

A flow-mqectlon system for the chemdummometnc determmatlon of o-glucose m serum with an lmmobdlzed pyranose oxldase reactor IS described Pyranose oxldase IS lmmobdlzed on controlled-pore glass beads and packed mto a stamless-steel column Serum (100 nl) IS dduted lOWfold with water Sample solution (1

Flow-injection determination of 1,5-anhy
โœ Nobutoshi Kiba; Fumito Ueda; Kazuya Saegusa; Yuusuke Toto; Motohisa Furusawa; Ta ๐Ÿ“‚ Article ๐Ÿ“… 1993 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 423 KB

A flow-mjectlon system wth a separation column and an unmobdlzed enzyme reactor 1s described for the determmatlon of l$anhydro-o-glucitol in serum Serum samples diluted mth water are injected into an amon-exchange column (4 cm x 4 mm I d ) The eluate 1s passed through an unmobdlzed pyranose oxldase