๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

A Chemiluminescence-Flow Injection Analysis of Serum 3-Hydroxybutyrate Using a Bioreactor Consisting of 3-Hydroxybutyrate Dehydrogenase and NADH Oxidase

โœ Scribed by M. Tabata; M. Totani


Publisher
Elsevier Science
Year
1995
Tongue
English
Weight
433 KB
Volume
229
Category
Article
ISSN
0003-2697

No coin nor oath required. For personal study only.

โœฆ Synopsis


We describe a simple method for the highly sensitive chemiluminescence--flow injection analysis of 3-hydroxybutyrate in serum using a bioreactor column consisting of the two immobilized enzymes, 3-hydroxybutyrate dehydrogenase and NADH oxidase. The method was based on measuring the level of chemiluminescence formed by the reaction of a luminol-hexacyanoferrate mixture with hydrogen peroxide. The hydrogen peroxide was produced by the NADH oxidase reaction from NADH which was formed in the conversion of 3-hydroxybutyrate to acetoacetate by the 3-hydroxybutyrate dehydrogenase reaction. Among three immobilized enzyme columns, a coimmobilized, small 3-hydroxybutyrate dehydrogenase/NADH oxidase bioreactor alone (2 x 20 mm i.d.) readily hydrolyzed all of the injected 3-hydroxybutyrate into acetoacetate, although 3-hydroxybutyrate dehydrogenase catalyzed the reversible reaction. The present method generated linearity of the data up to 1.5 mM 3-hydroxybutyrate with satisfactory precision, reproducibility, and accurate reaction recoveries. The results from 3-hydroxybutyrate correlated satisfactorily with those obtained by other well-established methods. The coimmobilized 3-hydroxybutyrate dehydrogenase/NADH oxidase reactor unit showed good operational stability over a 5-week period, during which it was repeatedly used for 1500 analyses.


๐Ÿ“œ SIMILAR VOLUMES


Determination of 3-hydroxybutyrate in se
โœ Nobutoshi Kiba; Hidekazu Koemado; Junko Inagaki; Motohisa Furusawa ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 451 KB

A flow-injection system with a co-immobilized enzyme reactor is described for the determination of 3-hydroxybutyrate. 3-Hydroxybutyrate dehydrogenase and NADH oxidase were immobilized on aminated poly (vinyl alcohol) beads and packed into a stainless-steel column (5 cm X 4 mm i.d.). Serum was dilute

Flow-injection determination of 3-hdroxy
โœ Nobutoshi Kiba; Hidekazu Koemado; Motoshisa Furusawa ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 414 KB

A flow-injection system for the determination of 3-hydroxybutyrate in serum is described. 3-Hydroxybutyrate dehydrogenase is immobilized on poly(vinyl alcohol) beads and incorporated in a flow-injection system. 1-Methoxy-Smethylphenazinium methylsulphate reacts with enzymatically generated NADH to g