𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Flow-injection determination of 1,5-anhydroglucitol in serum with an immobilized pyranose oxidase reactor and chemiluminescence detection

✍ Scribed by Nobutoshi Kiba; Fumito Ueda; Kazuya Saegusa; Yuusuke Toto; Motohisa Furusawa; Takeshi Yamane


Publisher
Elsevier Science
Year
1993
Tongue
English
Weight
423 KB
Volume
271
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.

✦ Synopsis


A flow-mjectlon system wth a separation column and an unmobdlzed enzyme reactor 1s described for the determmatlon of l$anhydro-o-glucitol in serum Serum samples diluted mth water are injected into an amon-exchange column (4 cm x 4 mm I d ) The eluate 1s passed through an unmobdlzed pyranose oxldase reactor (5 cm x 4 mm I d ) The hydrogen permde produced IS detected chemdurmnometncally Hnth a lummol-hexacyanoferrate(II1) reactlon The cahbratlon graph 1s hnear over the range 4 x lo-'-2 x 10m4 M, the detection hmlt 1s 2 x lo-' M The sample throughput 1s 20 h-' with a relative standard dewatlon of less than 2 5%


πŸ“œ SIMILAR VOLUMES


Flow-injection determination of glucose
✍ Nobutoshi Kiba; Fumito Ueda; Motohisa Furusawa; Takeshi Yamane πŸ“‚ Article πŸ“… 1992 πŸ› Elsevier Science 🌐 English βš– 386 KB

A flow-mqectlon system for the chemdummometnc determmatlon of o-glucose m serum with an lmmobdlzed pyranose oxldase reactor IS described Pyranose oxldase IS lmmobdlzed on controlled-pore glass beads and packed mto a stamless-steel column Serum (100 nl) IS dduted lOWfold with water Sample solution (1

Flow-injection determination of 3-hdroxy
✍ Nobutoshi Kiba; Hidekazu Koemado; Motoshisa Furusawa πŸ“‚ Article πŸ“… 1994 πŸ› Elsevier Science 🌐 English βš– 414 KB

A flow-injection system for the determination of 3-hydroxybutyrate in serum is described. 3-Hydroxybutyrate dehydrogenase is immobilized on poly(vinyl alcohol) beads and incorporated in a flow-injection system. 1-Methoxy-Smethylphenazinium methylsulphate reacts with enzymatically generated NADH to g

Spectrophotometric determination of magn
✍ J.M. FernΓ‘ndez-Romero; M.D.Luque de Castro; M. ValcΓ‘rcel; R. Quiles-Zafra πŸ“‚ Article πŸ“… 1993 πŸ› Elsevier Science 🌐 English βš– 446 KB

A spectrophotometric, continuous flow-injection, merging zones manifold including an enzyme reactor was used for the determination of magnesium ion in serum by exploiting the activating effect of MgfII) on the hydrolysis of o-nitrophenyl-B-o-galactopyranoside by j?-o-galactosidase immobiliied on con