Analytical techniques for the detection of small amounts of explosives (in the picogram range) are now involved in various application. Some of them concern soil, water and air monitoring in order to face environmental problems related to improper handling procedures either in stocking or in wasting
Electrospray Ionization Mass Spectrometry of Tetrodotoxin and Its Analogs: Liquid Chromatography/Mass Spectrometry, Tandem Mass Spectrometry, and Liquid Chromatography/Tandem Mass Spectrometry
β Scribed by Yuki Shoji; Mari Yotsu-Yamashita; Teruo Miyazawa; Takeshi Yasumoto
- Publisher
- Elsevier Science
- Year
- 2001
- Tongue
- English
- Weight
- 132 KB
- Volume
- 290
- Category
- Article
- ISSN
- 0003-2697
No coin nor oath required. For personal study only.
β¦ Synopsis
Tetrodotoxin (TTX), a powerful sodium channel blocker, usually exists as a mixture of its analogs (TTXs) in natural sources. Due to the structural variation, some analogs are difficult to detect using the postcolumn liquid chromatography-fluorescent detection (LC-FLD) system. Liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) analysis of TTXs can be achieved by a combination of chromatography on a reversed-phase column with long carbon chains (C30) and the mobile phase containing an ion pair reagent (ammonium heptafluorobutyrate). The relationship between the amount of applied standard TTX and its peak area on the mass chromatogram (m/z 320) showed good linearity over a range of 50-1000 pmol. The detection limit for TTX in the selected ion monitoring (SIM) mode was estimated to be 0.7 pmol (signal to noise ratio: 2). The tandem mass spectrometry (MS/MS) scan for the fragment ions of eight TTXs arising from the molecular ions provided characteristic spectra, and the structures of the origins of the prominent fragment ions were proposed. The intense fragment ions of TTX and 11-deoxyTTX were applicable to LC/MS/MS operated in the selected reaction monitoring mode. This method might be useful for further identification of TTXs.
π SIMILAR VOLUMES
Data-dependent liquid chromatography tandem mass spectrometry was utilized to identify leachables from adhesives used in pharmaceutical products. This approach affords a significant increase in the amount of data obtained from a single experiment. No information about the sample is needed a priori t
The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
Electrospray ionization multi-stage tandem mass spectrometry (ESI-MS(n)) and liquid chromatography coupled with on-line mass spectrometry (LC/MS/MS) were applied to characterize saponins in crude extracts from Panax ginseng. The MS(n) data of the [M - H](-) ions of saponins can provide structural in
Aqueous solutions containing synthetic mixtures of model methylated purine bases have been examined by liquid chromatography/electrospray tandem mass spectrometry. Efficient chromatographic separation together with characteristic fragment ions derived from selected parent molecular ions allowed fast
Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of