The quantitative analysis of pharmaceutical or environmental compounds represents an important application area of electrospray ionization (ESI) mass spectrometry (MS). Typically, these analyses are carried out using quadrupole mass analyzers. Recently, several other mass spectrometric configuration
Development of an ion trap / linear time-of-flight mass spectrometer with electrospray ionization for micro-column liquid chromatography detection
β Scribed by Randy W. Purves; Liang Li
- Publisher
- John Wiley and Sons
- Year
- 1995
- Tongue
- English
- Weight
- 679 KB
- Volume
- 7
- Category
- Article
- ISSN
- 1040-7685
No coin nor oath required. For personal study only.
β¦ Synopsis
Abstract
A linear timeβofβflight (TOF) mass spectrometer equipped with a quadrupole ion trap for ion storage was developed for mass analysis of ions generated by electrospray ionization (ESI). With this technique, the continuous ion beam from the ESI source is collimated by a set of focusing lenses into the ion trap where the ions are accumulated for a predetermined period of time. Extraction of the ions into the flight tube of the TOF mass spectrometer is achieved by applying a short duration voltage pulse to the exit endcap of the ion trap. The extraction frequency is variable, but is typically set at 10 Hz. It was shown that with a linear TOF mass spectrometer, mass resolution in the range of 600β950 can be routinely obtained. It was also demonstrated that a complete mass spectrum of bradykinin can be obtained with a direct injection of 75 fmol, or 0.5 ΞΌL of 150 nM of sample solution. Buffer gas pressure and the energy of the ions entering the ion trap, were found to be the key parameters in obtaining this sensitivity and resolution. In addition, the ESI ion trap/TOF system was developed and applied for microcolumn liquid chromatography detection of a simple protein mixture. Β© 1995 John Wiley & Sons, Inc.
π SIMILAR VOLUMES
## Abstract A new tandem timeβofβflight mass spectrometer with an electrospray ionization ion source βESIβTOF/quadTOFβ was designed and constructed to achieve the desired aim of structural elucidation via highβenergy collisionβinduced dissociation (CID), and the simultaneous detection of all fragme
Packed-capillary high-performance liquid chromatography (HPLC) was successfully coupled with an ion trap storage/reflectron time-of-flight mass spectrometer (LC/IT/reTOFMS) through an electrospray ionization interface for protein structural elucidation. Using the total-ion storage capabilities of th
In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourie
Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) Ξ²-chain. The Hb Ξ±-and Ξ²-chains are separated and
A data system based upon a 200MHz transient recorder interface card in a Pentium PC computer is demonstrated for on-line analysis of microbore high-performance liquid chromatography (HPLC), capillary HPLC and capillary electrophoresis (CE) separations using a fast and sensitive ion-trap storage/refl