โœฆ Synopsis


A data system based upon a 200MHz transient recorder interface card in a Pentium PC computer is demonstrated for on-line analysis of microbore high-performance liquid chromatography (HPLC), capillary HPLC and capillary electrophoresis (CE) separations using a fast and sensitive ion-trap storage/reflectron timeof-flight mass spectrometric detector (IT-reTOFMS). Under the control of a user-written program, the system is capable of conducting the data acquisition and storage for a minimum of 30 min, at rates exceeding 10 Hz, of individual mass spectra containing 16000 data points having lOnsec resolution. The capability is mainly attributed to the use of a data reduction scheme in which only mass intensities higher than a preset threshold are saved as indexed flight-timelintensity pairs. This produces a typical reduction ratio of 309 in data set size, yielding faster storage with smaller file size, and permits the complete set of mass spectra to be held in the computer's memory. In addition, the data system is capable of displaying, for real-time evaluation of the analysis, each individual mass spectrum and the total-ion chromatogram. Further, the selected-ion chromatograms of given masses and a 3-dimensional topographic map describing a separation process can be rapidly generated from the collected data for the unambiguous and high fidelity identification of target analytes in a complex mixture.


๐Ÿ“œ SIMILAR VOLUMES


Capillary Liquid Chromatography Coupled
โœ Mark G. Qian; Kefei Zheng; Yajuan Chen; Christina L. Chang; Samir M. Hanash; Dav ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 811 KB

Packed-capillary high-performance liquid chromatography (HPLC) was successfully coupled with an ion trap storage/reflectron time-of-flight mass spectrometer (LC/IT/reTOFMS) through an electrospray ionization interface for protein structural elucidation. Using the total-ion storage capabilities of th

Development of a capillary high-performa
โœ Ling He; Jing-Tao Wu; Steve Parus; David M. Lubman ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 207 KB ๐Ÿ‘ 3 views

In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourie

The Use of On-line Capillary Electrophor
โœ Michael X. Li; Jing-Tao Wu; Lin Liu; David M. Lubman ๐Ÿ“‚ Article ๐Ÿ“… 1997 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 204 KB ๐Ÿ‘ 3 views

Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) ฮฒ-chain. The Hb ฮฑ-and ฮฒ-chains are separated and