Doping control studies for the detection of clenbuterol in human urine was studied. Confirmation was achieved by trifluoroacetylation after cyclic fluorophenylboronation to produce FPBA-clenbuterol, for derivatization over 10 min at 80 Β°C, measured using negative chemical ionization (NICl) and NICl-
Determination of the sensitivity of an external source ion trap tandem mass spectrometer using dimethyl ether chemical ionization
β Scribed by Wu, Hui-Fen; Lin, Ya-Ping
- Publisher
- John Wiley and Sons
- Year
- 1999
- Tongue
- English
- Weight
- 50 KB
- Volume
- 34
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
β¦ Synopsis
Determination of the Sensitivity of an External Source Ion Trap Tandem Mass Spectrometer Using Dimethyl Ether Chemical Ionization
Tandem mass spectrometry is a rapid and powerful analytical technique that can provide trace mixture analysis and structure elucidation. The ion trap mass spectrometer has been widely used since it became commercially available in 1983. The reason is attributed to its tandem mass capability.
Within the last decade, a number of studies of ion-molecule reactions of dimethyl ether (DME) ions in the ion trap mass spectrometer have been published by Brodbelt and co-workers. 1,2 Two main reagent ions, of m/z 45 CH 3 O CH 2 C and 47 CH 3 OHCH 3 C , are generated when dimethyl ether is applied as a chemical ionization (CI) reagent gas. 1 According to Colorado and Brodbelt, 3 when DME reacts with compounds possessing
π SIMILAR VOLUMES
Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and
A procedure is described for the determination of three characteristic b-agonists (clenbuterol, terbutalin and salbutamol) based on the formation of the corresponding protonated molecules and related collisional experiments. Quantification was carried out on selected collisional fragments and the re
In this work we describe a micro-electrospray ionization source equipped with an atmospheric pressure external ion shutter. The solenoid-activated shutter prevents the electrospray plume from entering the inlet capillary unless triggered to the 'open' position. When in the 'closed' position, a stabl
Acetonitrile may be used as a chemical ionization reagent gas in ion-trap mass spectrometry for the location of double bonds in functionalized long-chain monoenes. [C 3 H 4 N] , derived from acetonitrile, reacts with carbon-carbon double bonds, generating one or a pair of fragment ions characteristi