𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of the sensitivity of an external source ion trap tandem mass spectrometer using dimethyl ether chemical ionization

✍ Scribed by Wu, Hui-Fen; Lin, Ya-Ping


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
50 KB
Volume
34
Category
Article
ISSN
1076-5174

No coin nor oath required. For personal study only.

✦ Synopsis


Determination of the Sensitivity of an External Source Ion Trap Tandem Mass Spectrometer Using Dimethyl Ether Chemical Ionization

Tandem mass spectrometry is a rapid and powerful analytical technique that can provide trace mixture analysis and structure elucidation. The ion trap mass spectrometer has been widely used since it became commercially available in 1983. The reason is attributed to its tandem mass capability.

Within the last decade, a number of studies of ion-molecule reactions of dimethyl ether (DME) ions in the ion trap mass spectrometer have been published by Brodbelt and co-workers. 1,2 Two main reagent ions, of m/z 45 CH 3 O CH 2 C and 47 CH 3 OHCH 3 C , are generated when dimethyl ether is applied as a chemical ionization (CI) reagent gas. 1 According to Colorado and Brodbelt, 3 when DME reacts with compounds possessing


πŸ“œ SIMILAR VOLUMES


Determination of derivatized clenbuterol
✍ JeongAe Lee; Dong-seok Lho; Myungsoo Kim; Won Lee; Yunje Kim πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 151 KB πŸ‘ 2 views

Doping control studies for the detection of clenbuterol in human urine was studied. Confirmation was achieved by trifluoroacetylation after cyclic fluorophenylboronation to produce FPBA-clenbuterol, for derivatization over 10 min at 80 Β°C, measured using negative chemical ionization (NICl) and NICl-

Analysis of a commercial preparation of
✍ Chien-Chen Lai; Pei-Lun Tsai; Cheng Yu; Guor-Rong Her πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 114 KB πŸ‘ 2 views

Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and

Positive chemical ionization and tandem
✍ Biancotto, Giancarlo; Angeletti, Roberto; Traldi, Pietro; Guidugli, Federico πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 158 KB πŸ‘ 2 views

A procedure is described for the determination of three characteristic b-agonists (clenbuterol, terbutalin and salbutamol) based on the formation of the corresponding protonated molecules and related collisional experiments. Quantification was carried out on selected collisional fragments and the re

A gated-beam electrospray ionization sou
✍ Steven A. Hofstadler; Kristin A. Sannes-Lowery; Richard H. Griffey πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 142 KB πŸ‘ 2 views

In this work we describe a micro-electrospray ionization source equipped with an atmospheric pressure external ion shutter. The solenoid-activated shutter prevents the electrospray plume from entering the inlet capillary unless triggered to the 'open' position. When in the 'closed' position, a stabl

Determination of the double bond positio
✍ Neil J. Oldham; AleΕ‘ SvatoΕ‘ πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 90 KB πŸ‘ 2 views

Acetonitrile may be used as a chemical ionization reagent gas in ion-trap mass spectrometry for the location of double bonds in functionalized long-chain monoenes. [C 3 H 4 N] , derived from acetonitrile, reacts with carbon-carbon double bonds, generating one or a pair of fragment ions characteristi