A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),
Determination of derivatized clenbuterol by use of gas chromatography and tandem mass spectrometry on an ion trap using negative ion chemical ionization
โ Scribed by JeongAe Lee; Dong-seok Lho; Myungsoo Kim; Won Lee; Yunje Kim
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 151 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
โฆ Synopsis
Doping control studies for the detection of clenbuterol in human urine was studied. Confirmation was achieved by trifluoroacetylation after cyclic fluorophenylboronation to produce FPBA-clenbuterol, for derivatization over 10 min at 80 ยฐC, measured using negative chemical ionization (NICl) and NICl-tanden mass spectrometry (MS/MS) on an ion trap mass spectrometer. In the NICl-MS/MS mode, the m/z 440 ion was selected as the precursor ion. This ion may be formed from FPBA-clenbuterol trifluoroacetate, which has a molecular weight of 476, having lost HCl. Derivatized clenbuterol was detected to 50 fg/mL, in spiked human urine. We applied the above procedure to two positive samples, one as a proficiency test and the other for reaccreditation, and achieved good results.
๐ SIMILAR VOLUMES
A gas chromatography/mass spectrometry method is described which uses negative ion chemical ionization and tandem mass spectrometry for the determination of anabolic steroid metabolites. Four anabolic steroid metabolites to be derivatized by Pentafluoropropionic anhydride (PFPA) were determined usin
A novel chemical ionization/fast atom bombardment (CI/FAB) source was used to analyse alkenes by chemical ionization mass spectrometry (CI-MS) using copper ions as the ionizing agent. The Cu Y -CI mass spectra showed abundant pseudomolecular adduct ions [alkene-Cu] Y and characteristic fragment ions
## Determination of the Sensitivity of an External Source Ion Trap Tandem Mass Spectrometer Using Dimethyl Ether Chemical Ionization Tandem mass spectrometry is a rapid and powerful analytical technique that can provide trace mixture analysis and structure elucidation. The ion trap mass spectromet
Because of the lack of a UV chromophore and their much smaller abundances in comparison with the major component, the minor components in erythromycin estolate preparations are difficult to analyze by high performance liquid chromatography ultraviolet (HPLC-UV). Tentative assignment of the major and