𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Determination of four anabolic steroid metabolites by gas chromatography/mass spectrometry with negative ion chemical ionization and tandem mass spectrometry

✍ Scribed by Man Ho Choi; Bong Chul Chung; Myungsoo Kim; Jeongeun Choi; Yunje Kim


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
164 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


A gas chromatography/mass spectrometry method is described which uses negative ion chemical ionization and tandem mass spectrometry for the determination of anabolic steroid metabolites. Four anabolic steroid metabolites to be derivatized by Pentafluoropropionic anhydride (PFPA) were determined using gas chromatography/mass spectrometry (GC/MS) with negative chemical ionization (NCI) and NCI/MS/MS. The repeatability and reproducibility of this procedure were in the range of 5.3-9.7% and 6.1-10.2%, respectively. This method of derivatization with PFPA for NCI and NCI/MS/MS was useful to determine four metabolites of nandrolone, dromostanolone, methenolone and boldenone. The derivatized metabolites of boldenone could be detected to 2 ppb and the other three steroids could be detected to 25 ppb in urine at a signal-to-noise ratio of S/N = 3.


πŸ“œ SIMILAR VOLUMES


Determination of anabolic steroids by ga
✍ Man Ho Choi; Bong Chul Chung; Won Lee; Un Chul Lee; Yunje Kim πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 118 KB πŸ‘ 1 views

A gas chromatography/mass spectrometry (GC/MS) method is described which uses negative ion chemical ionization (NCI) and tandem mass spectrometry (MS/MS) for the determination of eight anabolic steroids in human urine. Eight anabolic steroids were derivatized by heptafluorobutyric anhydride (HFBA),

Analysis of alkenes by copper ion chemic
✍ Fordham, P. J.; Chamot-Rooke, J.; Giudice, E.; Tortajada, J.; Morizur, J.-P. πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 164 KB πŸ‘ 1 views

A novel chemical ionization/fast atom bombardment (CI/FAB) source was used to analyse alkenes by chemical ionization mass spectrometry (CI-MS) using copper ions as the ionizing agent. The Cu Y -CI mass spectra showed abundant pseudomolecular adduct ions [alkene-Cu] Y and characteristic fragment ions

Determination of derivatized clenbuterol
✍ JeongAe Lee; Dong-seok Lho; Myungsoo Kim; Won Lee; Yunje Kim πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 151 KB πŸ‘ 1 views

Doping control studies for the detection of clenbuterol in human urine was studied. Confirmation was achieved by trifluoroacetylation after cyclic fluorophenylboronation to produce FPBA-clenbuterol, for derivatization over 10 min at 80 Β°C, measured using negative chemical ionization (NICl) and NICl-

Characterization of stereoisomeric furan
✍ C. Borges; M. A. Almoster Ferreira; H. Van den Heuvel; M. Claeys πŸ“‚ Article πŸ“… 1997 πŸ› John Wiley and Sons 🌐 English βš– 186 KB πŸ‘ 2 views

The present study deals with the mass spectrometric characterization of furanosidic compounds containing a 1,2-O-isopropylidene group using different mass spectrometric techniques: chemical ionization mass spectrometry and liquid secondary ion mass spectrometry together with metastable ion analysis

Stable Isotope Labelling and Determinati
✍ Leis, H. J.; Leis, M.; Windischhofer, W. πŸ“‚ Article πŸ“… 1996 πŸ› John Wiley and Sons 🌐 English βš– 482 KB πŸ‘ 1 views

A method for the quantitative measurement of the non-steroidal anti-inflammatory drug ketoprofen in human plasma and urine is presented. The assay is based on gas chromatographylnegative ion chemical ionization mass spectrometry. The preparation of stable isotope-labelled ketoprofen for use as an in

Identification of cyclopropene triacylgl
✍ Reiner Aichholz; Volker Spitzer; Eberhard Lorbeer πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 115 KB πŸ‘ 1 views

The seed oil of Choriosa speciosa, which is known to be rich in cyclopropene triacylglycerols, has been investigated by high-temperature gas chromatography using glass capillary columns coated with the stationary phase SOP-50 Ž . 50% diphenyl᎐50% dimethylpolysiloxane, methoxy terminated . Cycloprope