A gated-beam electrospray ionization source with an external ion reservoir. A new tool for the characterization of biomolecules using electrospray ionization mass spectrometry

โœ Scribed by Steven A. Hofstadler; Kristin A. Sannes-Lowery; Richard H. Griffey


Publisher
John Wiley and Sons
Year
1999
Tongue
English
Weight
142 KB
Volume
13
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

โœฆ Synopsis


In this work we describe a micro-electrospray ionization source equipped with an atmospheric pressure external ion shutter. The solenoid-activated shutter prevents the electrospray plume from entering the inlet capillary unless triggered to the 'open' position. When in the 'closed' position, a stable electrospray plume is maintained between the electrospray ionization (ESI) emitter and the electrically isolated face of the shutter. When the shutter is triggered, a 'slice' of ions is allowed to enter the inlet capillary and is subsequently accumulated in an external ion reservoir comprised of a radio frequency only (rf-only) hexapole and a pair of electrostatic elements. Following ion accumulation in the external ion reservoir, intact molecular ions of proteins, oligonucleotides, and noncovalent complexes can be stored for extended intervals (b30 minutes) prior to being transferred to the Fourier transform ion cyclotron resonance (FTICR) trapped ion cell for mass analysis. By introducing reactive gases directly into the external ion reservoir during the storage interval, ion-molecule reactions, such as H/D exchange, can be performed at high effective pressures. This scheme obviates the need for the long reaction times and delays associated with restoring base pressure in the trapped ion cell and allows H/D exchange reactions to be conducted in a fraction of the time required using conventional in-cell exchange approaches. The back face of the shutter arm contains an elastomeric material which can be positioned to seal the inlet to the mass spectrometer resulting in lower base pressure in the ion reservoir and the FTICR cell. Additionally, it is noted that blocking the ESI plume during non-accumulation events results in reduced fouling of the source electrodes and longer times between required source cleaning.


๐Ÿ“œ SIMILAR VOLUMES


The use of a stable internal mass standa
โœ Steven A. Hofstadler; Richard H. Griffey; Ljiljana Pasa-Tolic; Richard D. Smith ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 85 KB ๐Ÿ‘ 2 views

In this work we demonstrate the use of peptide as a stable internal mass standard to obtain accurate mass measurements of infrared multiphoton dissociation (IRMPD) generated phosphorothioate oligonucleotide fragment ions. Because oligonucleotides are more readily dissociated in the gas phase by IRMP

Reverse-phase capillary high performance
โœ Katalin F. Medzihradszky; Marc J. Besman; A. L. Burlingame ๐Ÿ“‚ Article ๐Ÿ“… 1998 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 226 KB ๐Ÿ‘ 1 views

The B-domain of recombinant human Factor VIII comprises 909 amino acids and is extensively N-and Oglycosylated, in that at least 20 different sites are occupied by numerous carbohydrate structures. This domain was incubated with trypsin and subjected to liquid chromatography electrospray ionization