Determination of methionine by gas-liquid chromatography: Modifications in its application to legumes and cereals

✍ Scribed by Alexander Duncan; Gabrielle M. Ellinger; Robert T. Glennie


Publisher
John Wiley and Sons
Year
1984
Tongue
English
Weight
295 KB
Volume
35
Category
Article
ISSN
0022-5142

No coin nor oath required. For personal study only.

✦ Synopsis


Abstract

Peptide‐bound methionine when reacted with CNBr releases methyl thiocyanate which is quantitatively measured by gas–liquid chromatography. Seeds of varieties of legume contain γ‐glutamyl‐S‐methylcysteine, which also reacts with CNBr to give methyl thiocyanate, which results in elevated apparent methionine values. An extraction procedure for its removal was developed and applied to many legume varieties. Methionine values agreed with those obtained by ion‐exchange chromatography after performic acid oxidation; an exception was Phaseolus mungo (black gram). Samples of Ph. mungo from several sources all contained substantial amounts of free methionine but, as no γ‐glutamyl‐S‐methylcysteine was‐present, the need for extraction was eliminated. For the determination of methionine in cereals, conditions were adapted to decrease gel formation in the presence of formic acid and CNBr, and to eliminate interference at the gas chromatography stage. This was achieved by a mild acid hydrolysis prior to CNBr reaction, conditions for which are described.


📜 SIMILAR VOLUMES


Determination of midazolam and its major
✍ Coassolo, P. ;Aubert, C. ;Sumirtapura, Y. ;Cano, J. P. 📂 Article 📅 1982 🏛 John Wiley and Sons 🌐 English ⚖ 472 KB 👁 2 views

## Abstract A sensitive gas liquid chromatographic (GLC) assay was developed for plasma determinations of 8‐chloro‐6‐(2′ ‐fluorophenyl)‐1‐methyl‐4__H__‐imidazo[1,5 α][1,4]benzodiazepine (compound I) and its hydroxymethylimidazo metabolite (compound II). The internal standards used were 8‐chloro‐6‐(

On-line high performance liquid chromato
✍ Chappell, Colin G. ;Creaser, Colin S. ;Shepherd, Martin J. 📂 Article 📅 1993 🏛 John Wiley and Sons 🌐 English ⚖ 425 KB

## Abstract The combination of high performance liquid chromatography interfaced on‐line with multidimensional gas chromatography (HPLC–GC–GC) is described. The HPLC column was interfaced to the GC via an on column interface, with automated pneumatic control of solvent evaporation and GC column swi

Determination of tectoridin in rat plasm
✍ Taiming Liu; Zhuo Chen; Yuyi Guo; Xuehua Jiang; Guo Ma 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 148 KB 👁 2 views

## Abstract A simple, specific and sensitive HPLC method with UV detection was developed and validated for the determination of tectoridin in rat plasma for the first time. Chromatographic separation was performed on a Welchrom^TM^ C~18~ column (150 × 4.6 mm, i.d., 5 µm) at a flow rate of 1.0 mL mi

Determination of aflatoxin B1 in cereals
✍ Neda Sheijooni-Fumani; Jalal Hassan; Seyed R. Yousefi 📂 Article 📅 2011 🏛 John Wiley and Sons 🌐 English ⚖ 193 KB

## Abstract A simple and rapid method based on homogeneous liquid–liquid extraction coupled to HPLC with fluorescence detection was developed for the determination of aflatoxin B1 (AFB1) in the rice and grain samples after post‐column derivatization. The proposed method eliminated the use of immuno