## Abstract A sensitive GC‐ECD assay has been developed for the simultaneous determination of midazolam (I) and its α‐hydroxy metabolite (II) in plasma. The assay involves extraction of both compounds into ether at alkaline pH (pH 12), followed by silylation of the α‐hydroxy metabolite with N,O‐bis
Determination of midazolam and its major hydroxy metabolite in plasma by gas liquid chromatography. Application to a pharmacokinetic study
✍ Scribed by Coassolo, P. ;Aubert, C. ;Sumirtapura, Y. ;Cano, J. P.
- Publisher
- John Wiley and Sons
- Year
- 1982
- Tongue
- English
- Weight
- 472 KB
- Volume
- 5
- Category
- Article
- ISSN
- 0935-6304
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
A sensitive gas liquid chromatographic (GLC) assay was developed for plasma determinations of 8‐chloro‐6‐(2′ ‐fluorophenyl)‐1‐methyl‐4__H__‐imidazo[1,5 α][1,4]benzodiazepine (compound I) and its hydroxymethylimidazo metabolite (compound II). The internal standards used were 8‐chloro‐6‐(2′ ‐chlorophenyl)‐1 ‐methyl‐4__H__‐imidazo[1,5 α][1,4]benzodiazepine (compound VI) and 7‐chloro‐5‐(2′ ‐fluorophenyl)‐1, 3‐dihydro‐1‐(hydroxyethyl)‐2__H__‐1,4‐benzodiazepin‐2‐one (compound VII) for compounds I and II, respectively. Following extraction, and silylation for compound II, compounds I and II were analyzed by GLC using a glass column packed with 5% OV‐101 on Gas‐Chrom Q, and a ^63^Ni electron‐capture detector. The GLC method was validated by a CI‐GC/MS technique. The detection limit of the assay is approximately 4–5 ng/ml for compound I and 3 ng/ml for compound II. The method was used in comparative pharmacokinetic studies of the distribution of the two compounds in arterial and venous blood.
📜 SIMILAR VOLUMES
A high-performance liquid chromatographic method using a fluorometric detector was developed for the determination of plasma concentrations of the antidepressant indalpine (I) and its major metabolite 4-[2-(3-indolyl)ethyl]-2-piperidinone (PK). the same procedure was used to measure, in urine, level
## Abstract A simple, specific and sensitive HPLC method with UV detection was developed and validated for the determination of tectoridin in rat plasma for the first time. Chromatographic separation was performed on a Welchrom^TM^ C~18~ column (150 × 4.6 mm, i.d., 5 µm) at a flow rate of 1.0 mL mi
Determination of apomorphine in canine plasma by liquid chromatography-electrospray ionization mass spectrometry and its application to a pharmacokinetic study An LC-ESI-MS method was developed and validated for the assay of apomorphine in canine plasma using one-step liquid -liquid extraction. The
## Abstract A gas chromatographic method is reported for simultaneously determining acetyl‐methadol, noracetylmethadol, and dinoracetylmethadol in plasma. Minimum detectable concentrations are 10 ng ml^−1^ for acetylmethadol using a flame ionization detector, and 5 and 25 ng ml^−l^ for noracetylmet