✦ Synopsis


Abstract

High‐performance liquid chromatography (HPLC) coupled to atmospheric pressure chemical ionization (APCI) mass spectrometry was used for the separation and detection of amino acid and peptide enantiomers. With detection limits as low as 250 pg, 25 amino acids enantiomers were baseline resolved on a Chirobiotic T chiral stationary phase. APCI demonstrated an order of magnitude better sensitivity over electrospray ionization (ESI) for free amino acids and low molecular mass peptides at the high LC flow‐rates necessary for rapid analysis. As the peptide chain length increased (peptides with M~r~ ≥ 300 Da), however, ESI proved to be the more ideal atmospheric pressure ionization source. A mobile phase consisting of 1% (w/w) ammonium trifluoroacetate in methanol and 0.1% (w/w) formic acid in water increased the sensitivity of the APCI method significantly. A step gradient was then used to separate simultaneously all 19 native protein amino acid enantiomers in less than 20 min using extracted ion chromatograms. Copyright © 2004 John Wiley & Sons, Ltd.


📜 SIMILAR VOLUMES


Analysis of Polyunsaturated Fatty Acids
✍ Řezanka, Tomáš 📂 Article 📅 2000 🏛 John Wiley and Sons 🌐 English ⚖ 73 KB 👁 2 views

Analysis of polyunsaturated fatty acids using high performance liquid chromatography -atmospheric pressure chemical ionization mass spectrometry is described. The standard fatty acid methyl esters from 16 to 22 carbons were analyzed by LC-MS with APCI. The effect of orifice voltage and total carbon

Analysis of bacteriohopanepolyols in sed
✍ Paul A. Fox; James Carter; Paul Farrimond 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 85 KB 👁 2 views

We report the new application of negative ion atmospheric pressure chemical ionization (APCI) to the detection of composite bacteriohopanepolyols in bacterial and sedimentary (or other natural environmental) samples. The method employs the addition of dichloromethane to the high performance liquid c

High Performance Liquid Chromatography/A
✍ Philip A. Clarke; Karen A. Barnes; James R. Startin; Frank I. Ibe; Martin J. She 📂 Article 📅 1996 🏛 John Wiley and Sons 🌐 English ⚖ 393 KB 👁 2 views

The performance of electrospray ionization and atmospheric pressure chemical ionisation (APCI) for the analysis of carotenoids was investigated. On our instrument, APCI produced spectra which were readily interpreted, and the positive-ion mode proved applicable to all of the compounds. The separatio

Molecular species of sphingomyelin: dete
✍ Karlsson, Anders Å.; Michélsen, Peter; Odham, Göran 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 144 KB 👁 3 views

In a sphingomyelin-enriched sample of polar lipids from bovine milk, molecular species of intact sphingomyelin were separated by normal-phase high-performance liquid chromatography and detected by mass spectrometry (MS) for structural information. First, by using electrospray with positive ionizatio

Analysis of insect triacylglycerols usin
✍ Edita Kofroňová; Josef Cvačka; Pavel Jiroš; David Sýkora; Irena Valterová 📂 Article 📅 2009 🏛 John Wiley and Sons 🌐 English ⚖ 355 KB 👁 1 views

## Abstract An HPLC non‐aqueous reversed‐phase separation system was adapted for analyzing insect triacylglycerols (TAG). The method uses two conventional Nova‐Pak C18 columns connected in series, for a total length of 45 cm. The mobile phase gradient is mixed from acetonitrile and 2‐propanol, and

The Analysis of β-Blockers by Capillary
✍ Kathryn A. Hutton; David E. Games 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 285 KB 👁 2 views

Capillary liquid chromatography/mass spectrometry (LC/MS) is usually performed using electrospray ionization. Atmospheric pressure chemical ionization (APCI) has not been used since the flow rates involved (1-10 µL/min) are too low to effect ionization with a standard APCI source. Using a 320 µm ؋ 1