✦ Synopsis


In the proposed procedure, the determination of salbutamol with Folin-Ciocalteau reagent (FC) using a flow injection analysis technique (FIA) with spectrophotometric detection at 750 nm is described. The lab-made FIA system consisted of a peristaltic pump Gilson Minipulse 3 equipped with Tygon tubes, double 6-port external Vici Valco sample injector and S 2000/SAD500 fiber optic spectrophotometer. It was controlled by a PC with use of originally compiled LabVIEW ®supported software containing the mathematical library with various statistical functions for off-line data evaluation. Concentration, volume of reagents and flow rate were optimised by a simplex method. The proposed system was used for the direct determination of salbutamol sulphate in the tablets and the human urine without preliminary pre-treatment of the sample. The negative effect of interfering substances (excipients of the tablets and matrix of the urine) is overcome by a solid phase extraction (SPE), when salbutamol is adsorbed on the solid phase in the microcolumn, which is integrated directly into the flow system. Pre-treatment of the sample takes place directly in the flowing stream. The sample throughput without carryover of on-line SPE was 60-80 samples per hour. With the SPE column (Baker-carboxylic acid), salbutamol was determined in the linear range from 1 to 15 g ml -1 (R.S.D. = 1.2%), with detection limit (3σ ) 0.1 g ml -1 and a frequency of 40-60 samples per hour in the water solutions. The salbutamol was determined in the linear range from 2 to 20 g ml -1 (R.S.D. = 1.7%), with detection limit (3σ ) 1 g ml -1 and a frequency of 30 samples per hour in the samples of the human urine.


📜 SIMILAR VOLUMES


Flow-injection in-valve solid-phase extr
✍ Kate Grudpan; Jaroon Jakmunee; Ponlayuth Sooksamiti 📂 Article 📅 1998 🏛 John Wiley and Sons 🌐 English ⚖ 202 KB 👁 2 views

Flow-injection analysis (FIA) system incorporating in-valve solid-phase extraction microcolumn for on-line separation and preconcentration using a new resin, U/TEVA.Spec, has been proposed for the spectrophotometric determination of uranium in geological samples using 4-(2-pyridylazo) resorcinol (PA

Flow-injection extraction spectrophotome
✍ D. Thorburn Burns; N. Chimpalee; D. Chimpalee; K. Leiwongcharoen 📂 Article 📅 1992 🏛 Elsevier Science 🌐 English ⚖ 267 KB

Salbutamol can be determined spectrophotometrically at 605 nm after flow-injection extraction into chloroform after oxidative coupling with 4-amino-N,N-dimethylaniline. The carrier stream is distilled water and the reagents streams contain 5% (w/v) sodium hydrogencarbonate, 0.5% (w/v) potassium hex

Spectrophotometric determination of tota
✍ Wolfgang Frenzel; Stephanie Krekler 📂 Article 📅 1995 🏛 Elsevier Science 🌐 English ⚖ 882 KB

Flow injection ailalysis (FIA) procedures for the spectrophotometric determination of phenol involving m-line concentration by solvent and sorbent extraction have been developed. The imine product formed in the reaction between phenol and 4-aminoantipyrine (6AAP) is either extracted into chloroform

On-line photochemical derivatization and
✍ A.Mellado Romero; G.Gomez Benito; J.Martínez Calatayud 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 476 KB

A flow-injection manifold is proposed for the on-line photochemical derivatization of ergonovine maleate with application to pharmaceutical formulations. The procedure is based on the reaction with p-dhnethylaminobenzaIdehyde in presence of iron and sulphuric acid medium. The reaction rate is improv

Flow injection, amperometric determinati
✍ Zuliang Chen; Ji Jin Yu; D. Brynn Hibbert 📂 Article 📅 1997 🏛 John Wiley and Sons 🌐 English ⚖ 302 KB

Ethanol in wines was determined by flow injection analysis with an amperometric detector using an oxidized nickel wire. Solid-phase extraction with a strong anion exchanger was used to remove interferences such as organic acids from the matrix, and the residue of the extraction was injected directly