Glucose oxidase from A. niger (EC 1.1.3.4) was physically entrapped between two dialysis membranes. The resultant enzyme-membrane sandwich reactors were employed in a standard Technicon dialyzer unit at 37Β°C and were found to perform efficiently in the automated analysis of aqueous glucose standards
A sequential method for determination of glucose and fructose involving the u8e of enzymes (hexokinase and glucose-6-phosphate dehydrogenase) immobilized on controlled-pore glass is proposed. The flow is selected so as to determine glucose or both sugars by fluorimetric determination of the NADH for