## Abstract The original article to which this Erratum referes was published in Rita Grandori,\* Irena Matecko and Norbert Müller. __Journal of Mass Spectrometry__, 2002; 37: 191–196.
Uncoupled analysis of secondary and tertiary protein structure by circular dichroism and electrospray ionization mass spectrometry
✍ Scribed by Rita Grandori; Irena Matecko; Norbert Müller
- Publisher
- John Wiley and Sons
- Year
- 2001
- Tongue
- English
- Weight
- 314 KB
- Volume
- 37
- Category
- Article
- ISSN
- 1076-5174
- DOI
- 10.1002/jms.272
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
An Erratum has been published for this article in Journal of Mass Spectrometry 38 (3) 2003, 345.
Electrospray ionization mass spectrometry (ESI‐MS) applied to protein conformational studies is a powerful new method that seems to provide specific information about protein tertiary structure. In this study, we analyzed the effect of trifluoroethanol (TFE) on a myoglobin peptide and cytochrome c (cyt c) at low pH by circular dichroism (CD) and ESI‐MS. These experiments show that coil‐to‐helix transition per se does not affect ESI mass spectra, confirming that this technique is insensitive to the local conformation of the polypeptidic chain and, rather, reports on the tertiary contacts characterizing different protein conformations. This property makes ESI‐MS an excellent method, complementary to CD, for the characterization of protein conformational changes. Fluorinated alcohols have been suggested to induce molten globule formation in acid‐unfolded cyt c. The experiments described here show that TFE does not induce major changes in the ESI mass spectrum of cyt c at pH 2.2, indicating that no stabilization of compact, globular structures is detectable under the conditions employed. On the other hand, even low concentrations of TFE (2–5%) are shown to destabilize the folded state of the protein around the mid‐point of its acid‐induced unfolding transition. Copyright © 2001 John Wiley & Sons, Ltd.
📜 SIMILAR VOLUMES
Bacterioopsin (BO) from Halobacterium halobium, as well as its V8-protease and CNBr fragments from the C-terminal region, were used to establish appropriate conditions for the mass determination of membrane proteins and peptides by electrospray mass spectrometry (ESI-MS). Of the tested solvents neat
We compared changes in the fluorescence, circular dichroism (CD) and multiply charged electrospray ionization mass spectrometry (ESI-MS) spectra of three calcium (Ca 2 )-binding proteins upon the binding of Ca . The proteins used were rat brain calbindin D 28K and two deletion mutants, one lacking E
Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteris
## Abstract Electrospray ionization mass spectrometry (ESI‐MS) was employed to monitor the heme release and the conformational changes of myoglobin (Mb) under different solvent conditions, and to observe ligand bindings of Mb. ESI‐MS, complemented by circular dichroism and fluorescence spectroscopy