Five metal complex azo compounds were analyzed using negative-ion electrospray ionization mass spectrometry (ESI-MS). Mass spectra of all compounds yield intense peaks corresponding to [M - H](-) ions without any fragmentation, where M denotes the neutral compound with a proton as the counterion. Un
Structural analysis of chromophore-labeled disaccharides and oligosaccharides by electrospray ionization mass spectrometry and high-performance liquid chromatography/electrospray ionization mass spectrometry
โ Scribed by Li, D. T.; Her, G. R.
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 296 KB
- Volume
- 33
- Category
- Article
- ISSN
- 1076-5174
No coin nor oath required. For personal study only.
โฆ Synopsis
Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteristic fragment ions under insource collision-induced dissociation (CID). These ions provided unambiguous assignment of the position of the glycosidic linkages. This approach was extended to the analysis of linkages and the sequence of the linkages of several linear oligosaccharides. Additionally, the anomeric conรguration of ABEE-labeled 1-3-, 1-4-and 1-6linked glucose disaccharides could be di โ erentiated according to the relative abundance of characteristic ions. Disaccharides with the same linkage but di โ erent monosaccharide compositions could be analyzed by on-line coupling of high-performance liquid chromatography with ESIMS.
๐ SIMILAR VOLUMES
Analysis of Vero Toxins 1 and 2 by High-performance Liquid Chromatography/Electrospray Ionization Mass Spectrometry During the past 10 years, disease outbreaks of hemorrhagic colitis (HC) and hemolyticรuremic syndrome (HUS) in humans have been increasing worldwide owing to the ingestion of beef and
Linalool, nerol, geraniol, citronellol and a-terpineol were phosphorylated and the products purified by adsorption chromatography on XAD-2. High performance liquid chromatography-tandem mass spectrometry (LC-MSMS) analysis using the electrospray ionization technique (ESI) revealed the occurrence of
The behaviour of 5-methyl-2'-deoxycytidine (m 5 dCyd, claimed to be a potential marker for leukaemia) during the electrospray process was studied. In particular, considerations concerning the effect of solution chemistry (e.g. analyte concentration, pH, etc.) on electrospray ionization mass spectra
A phospholipid mixture extracted from cultured cells was directly analyzed by capillary (Cap) liquid chromatography (LC)/electrospray ionization (ESI) mass spectrometry (MS). Using a quadrupole mass spectrometer, we analyzed positive molecular ions, negative molecular ions, positive fragment ions an
Analyses of oligosaccharide-malononitrile derivatives, which were obtained from the reactions of oligosaccharides with malononitrile under aqueous basic conditions, were conducted by on-line capillary liquid chromatography/electrospray ionization mass spectrometry in negative-ion mode. Among a varie