Upon exposure to ionizing radiation, DNA undergoes a variety of modifications including the production of a covalent bond between the nucleobase thymine and the amino acid tyrosine. These crosslinked lesions, produced in cells exposed to ionizing radiation, if unrepaired are thought to result in cel
Analysis of Hydrophobic Proteins and Peptides by Electrospray Ionization Mass Spectrometry
β Scribed by Johann Schaller; Bernhard Christian Pellascio; Urs Peter Schlunegger
- Publisher
- John Wiley and Sons
- Year
- 1997
- Tongue
- English
- Weight
- 465 KB
- Volume
- 11
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
Bacterioopsin (BO) from Halobacterium halobium, as well as its V8-protease and CNBr fragments from the C-terminal region, were used to establish appropriate conditions for the mass determination of membrane proteins and peptides by electrospray mass spectrometry (ESI-MS). Of the tested solvents neat formic acid gave the best results for BO (26 781.8 Β± 5.1 Da) and chloroform + methanol + water (2:5:2, v/v/v/) containing 2% acetic acid was best for the BO fragments (2461.5 Β± 0.2 Da, 7147.1 Β± 0.5 Da, 7748.0 Β± 0.4 Da) with an overall mass accuracy of about 0.01%.
The three subunits IIAB Man , IIC Man and IID Man of the mannose transporter complex in E. coli were used to establish conditions for liquid chromatography/electrospray mass spectrometry measurements (LC/ESI-MS). The subunits were separated by reversed-phase high-performance liquid chromatography using a water/formic acid gradient. Of the detergents used to solubilize the sample, the uncharged dodecylmaltoside and the positively charged dodecyltrimethylammoniumchloride had the most favorable influence on the separation and mass measurement by ESI-MS. For the first time the rather hydrophilic IIAB Man (34 920.8 Β± 6.7 Da) and the transmembrane IID Man (31 909.4 Β± 18.2 Da) subunits could be determined with a mass accuracy in the range of 0.01 to 0.05%. On the other hand no appropriate conditions could be found to determine the precise mass of IIC Man experimentally.
π SIMILAR VOLUMES
Non-covalent interactions between met-and leu-enkephalins and their antisense peptides were studied by electrospray ionization mass spectrometry. Mixtures of sense and antisense peptides gave both the corresponding homodimers and heterodimers. The relative abundance ratios of the heterodimer to that
Crude mixtures of difficult tetrapeptide cyclization reactions were analyzed by electrospray ionization mass spectrometry to optimize the production of cyclomonomer versus cyclodimer. The cationization phenomenon enabled the differentiation between monoprotonated and multiply charged ions of the sam
A novel method has been developed for the rapid desalting of proteins and peptides for electrospray ionization mass spectrometry (ESI-MS). Protein and peptide solutions having high salt concentrations were infused into a microdialysis tube which was directly interfaced with a micro-ESI source. The m
Disaccharides and linear oligosaccharides were labeled with p-aminobenzoic ethyl ester (ABEE) chromophore and analyzed by negative ion electrospray ionization mass spectrometry (ESIMS). The formation of glycosylamines rather than reductive amination in the labeling reaction produced many characteris