Tissue response around silicon nitride implants in rabbits
✍ Scribed by Cecilia C. Guedes e Silva; Bruno König Jr.; Marcelo José Carbonari; Marcelo Yoshimoto; Sérgio Allegrini Jr.; José Carlos Bressiani
- Publisher
- John Wiley and Sons
- Year
- 2007
- Tongue
- English
- Weight
- 329 KB
- Volume
- 84A
- Category
- Article
- ISSN
- 1549-3296
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
The chemical and dimensional stability associated with suitable fracture toughness and propitious tribological characteristics make silicon nitride–based ceramics potential candidates for biomedical applications, mainly as orthopedic implants. Considering this combination of properties, silicon nitride components were investigated in relation to their biocompatibility. For this study, two cylindrical implants were installed in each tibia of five rabbits and were kept in the animals for 8 weeks. During the healing time, tissue tracers were administrated in the animals so as to evaluate the bone growth around the implants. Eight weeks after the surgery, the animals were euthanized and histological analyses were performed. No adverse reactions were observed close to the implant. The osteogenesis process occurred during the entire period defined by the tracers. However, this process occurred more intensely 4 weeks after the surgery. In addition, the histological analyses showed that bone growth occurred preferentially in the cortical areas. Different kinds of tissue were identified on the implant surface, characterized by lamellar bone tissue containing osteocytes and osteons, by a noncalcified matrix containing osteoblasts, or by the presence of collagen III, which may change to collagen I or remain as a fibrous tissue. The results demonstrated that silicon nitride obtained according to the procedure proposed in this research is a biocompatible material. © 2007 Wiley Periodicals, Inc. J Biomed Mater Res, 2008
📜 SIMILAR VOLUMES
There is a possible role of reactive oxygen species (ROS) in the complication of implants although there is presently little information. The aim of this study was to investigate the alterations in lipid peroxidation (LP) and antioxidant enzyme activities in tissues surrounding implants in rabbits.
## Abstract Transcutaneous osseointegrated implants can improve function for select amputee patients, but infection serves as a significant limitation of implantable transcutaneous devices. This study examined the efficacy of an antimicrobial, pexiganan acetate (SUPONEX™), and a porous tantalum imp
It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, a
## Abstract The goal of this study was the in vivo evaluation of nanoporous titanium (Ti) implants bearing a covalently linked surface hyaluronan (HA) layer. Implant surface topography and surface chemistry were previously evaluated by scanning electron micorscopy and X‐ray photoelectron spectrosco
## Abstract Silicone rubber implants are clinically used in large numbers and elicit a mild tissue reaction. An occasional patient develops an accentuated reaction, an observation which has stimulated clinicians to try to understand this process more fully. The chemistry of medical silicone implant