It has been suggested that during wound healing microtextured surfaces can alter events at the interface between implant surface surface and surrounding tissues. To investigate this phenomenon, smooth and microtextured silicone rubber implants were implanted subcutaneously in rabbits for 3, 7, 42, a
Comparative study of antioxidant enzymes in tissues surrounding implant in rabbits
✍ Scribed by İsmail Ozmen; Mustafa Naziroglu; Ramazan Okutan
- Publisher
- John Wiley and Sons
- Year
- 2006
- Tongue
- English
- Weight
- 169 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0263-6484
- DOI
- 10.1002/cbf.1225
No coin nor oath required. For personal study only.
✦ Synopsis
There is a possible role of reactive oxygen species (ROS) in the complication of implants although there is presently little information. The aim of this study was to investigate the alterations in lipid peroxidation (LP) and antioxidant enzyme activities in tissues surrounding implants in rabbits. Thirty New Zealand albino male rabbits were used. They were randomly divided into five groups. The first group (I) was used as control. Groups II, III, IV and V were implanted with stainless steel, ceramic, titanium and polyethylene, respectively. One month after the administration of implant, the tissues surrounding the implant were carefully removed for antioxidant enzyme analysis. Glucose-6-phosphate dehydrogenase (G6PD), glutathione reductase (GR), superoxide dismutases (SOD), glutathione peroxidase (GPx), catalase (CAT) in tissues surrounding the implants in the groups II, III and IV were significantly (p < 0.05-p < 0.001) lower than in the control group although glutathione S-transferase (GST) activities and LP values were increased. CAT activity and LP level did not decrease in group V. In conclusion, these data demonstrate that there is an increase in lipid peroxidation in the tissues surrounding ceramic and titanium implants of animals whereas there is a decrease in antioxidant enzymes. Oxidative stress plays a very important role in the complications of ceramic and titanium implants. The polyethylene implant seems to be the best of the four implant materials tested.
📜 SIMILAR VOLUMES
Clinical studies suggest a role for polyethylene ( PE ) wear debris in the pathogenesis of osteolysis and loosening of total joint replacements. In this study, submicron particles of ultrahigh molecular weight PE (UHMWPE ) were placed around pressfit tibial hemiarthroplasties in rabbits to determine
Comparative studies were performed on the antioxidant enzyme activities and thiobarbituric acid reactive substance (TBARS) concentration in liver and red cells of two groups of rainbow trout (Oncorhynchus mykiss). The fish of the first group were cultured in freshwater and the others were adapted to
## Abstract The purpose of this study was to compare the integration in bone of uncoated free form fabricated cobalt chromium (CoCr) implants to the same implant with a calcium aluminate coating. The implants of cylindrical design with a pyramidal surface structure were press‐fit into the limbs of
Osseointegrated implants have a large potential for diverse clinical applications, including support for sutural expansion and facial prostheses. The objectives of this study were to evaluate: (1) the histomorphometric response of thin cortical bone to implant placement and (2) whether loading of th