The matrix suppression effect in matrix-assisted laser desorption/ionization: application to negative ions and further characteristics

✍ Scribed by Richard Knochenmuss; Volker Karbach; Ursula Wiesli; Kathrin Breuker; Renato Zenobi


Publisher
John Wiley and Sons
Year
1998
Tongue
English
Weight
143 KB
Volume
12
Category
Article
ISSN
0951-4198

No coin nor oath required. For personal study only.

✦ Synopsis


As recently shown for positive ions (Rapid Commun. Mass Spectrom. 10, 871 (1996)), small to moderate-sized analyte ions (`20 000 Da) can fully suppress all matrix signals in matrix-assisted laser desorption/ionization (MALDI) mass spectra at appropriate matrix:analyte mixing ratios. The technique is useful for removing matrix interferences and led to a model for primary ion formation mechanisms. We here extend the method to negative ions, and investigate the effects of analyte type and size on the matrix suppression concentration range. For a given matrix/analyte pair, suppression was observed in either positive-or negative-ion mode, but not both. Some matrices do not show the effect at all, which is attributed to unfavourable thermodynamics. The analyte concentration where suppression appears is correlated with the analyte molecular weight and supports the proximity requirement of the model. The dependence of matrix signals on analyte concentration is very similar in both modes, and may have implications for the role of plume reactions at low analyte concentrations. Delayed extraction was found to extend matrix suppression to lower analyte concentrations. Lack of homogenous matrix/analyte co-crystallization at low analyte concentrations is shown to prevent the appearance of matrix suppression or to modify the shape of the concentration curves in some cases. Evidence is presented for the activity of electronic excitations in IR as well as in UV MALDI.


πŸ“œ SIMILAR VOLUMES


Ionization in matrix-assisted laser deso
✍ Karas, Michael; GlοΏ½ckmann, Matthias; SchοΏ½fer, JοΏ½rgen πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 325 KB πŸ‘ 2 views

A new model for the ionization processes in UV matrix-assisted laser desorption/ionization (MALDI) which accounts for the major phenomena observed is presented and discussed. The model retains elements of earlier approaches, such as photoionization and photochemical reactions, but it redefines these

The initial ion velocity and its depende
✍ GlΓΌckmann, Matthias; Karas, Michael πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 255 KB πŸ‘ 2 views

Since the early days of matrix-assisted laser desorption/ionization (MALDI), measurements showing that MALDI ions and neutrals have high initial velocities have led to wide acceptance of the idea that a jet of released material entrains analyte ions. The initial velocity, which could previously be d

Application of matrix-assisted laser des
✍ Bertazzo, Antonella; Costa, Carlo V. L.; Allegri, Graziella; Favretto, Donata; T πŸ“‚ Article πŸ“… 1999 πŸ› John Wiley and Sons 🌐 English βš– 121 KB πŸ‘ 2 views

Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry was used to study melanogenesis starting from Dopa and dopamine, the latter considered one of the precursors of neuromelanins. These substrates were left to react with the peroxidase-H 2 O 2 system, which is postulated to play an

Application of matrix-assisted laser des
✍ Toshihisa Sumi; Tsuyoshi Sakaki; Hideki Ohba; Masao Shibata πŸ“‚ Article πŸ“… 2000 πŸ› John Wiley and Sons 🌐 English βš– 84 KB πŸ‘ 1 views

An analytical approach is described for the molecular weight characterization of glucose oligomers from cellulose which had been decomposed by hot-compressed water (HCW). Microcrystalline cellulose was decomposed to 18% of water insoluble fraction (WI) plus 82% of water soluble fraction (WS) by HCW