✦ Synopsis


A semimicrotitration device for reaction volumes of 0.5 to 2 ml and effective stirring of reaction solution or suspension is described. The principal part of the device is a combined glass electrode functioning as a reaction vessel (combined "cup"-glass electrode). Characteristics of the device are small volumes and great reliability. Nonspecific cholinesterase activities measured in rat plasma and liver tissue homogenates and compared with the activities of the same tissue and plasma samples measured radiometrically and spectrophotometrically illustrate the applicability of the device. The method is best suited for kinetic studies with multiple substrates of esterases, either in the soluble form or in tissue homogenates.


📜 SIMILAR VOLUMES


A modified assay for cholinesterase
✍ D.B. Hoover; J. Kosa; B.K. Colasanti; C.R. Craig 📂 Article 📅 1976 🏛 Elsevier Science 🌐 English ⚖ 228 KB
A rapid, simple radiometric assay for ch
✍ Carl D. Johnson; Richard L. Russell 📂 Article 📅 1975 🏛 Elsevier Science 🌐 English ⚖ 471 KB

A rapid and simple radiometric assay for cholinesterase, suitable for multiple determinations, has been developed. (aH-acetyl) choline is enzymatically hydrolyzed in a small reaction volume in a scintillation vial. The released [all]acetate is then extracted into a toluene-based scintillator added d

A new assay for cholinesterase potentiom
✍ L.H.Von Storp; G.G. Guilbault 📂 Article 📅 1972 🏛 Elsevier Science 🌐 English ⚖ 427 KB

## Cholincstcrase catalyses the hydrolysis of acetylcholine which acts at nerve endings ;is 11 transmitter of impulses from nerve to muscle fiber'. Among several analytical procedures which huvc been developed for the assay of cholincstcrase. lluorimctric and spcctrophotometric methods are very fr

Liposome immunomigration field assay dev
✍ Sui Ti A. Siebert; Stuart G. Reeves; Richard A. Durst 📂 Article 📅 1993 🏛 Elsevier Science 🌐 English ⚖ 903 KB

The feasibility of a simple, single-use immunomigration system has been demonstrated, using Alachlor as a model environmental contaminant. In the device, capillary action causes Alachlor and Alachlor-tagged, dye-containing liposomes to migrate through an anti-Ala&or antibody zone, on a plastic-backe