𝔖 Bobbio Scriptorium
✦   LIBER   ✦

Quantitative SENSE-MRSI of the human brain

✍ Scribed by David Bonekamp; Mari A. Smith; He Zhu; Peter B. Barker


Publisher
Elsevier Science
Year
2010
Tongue
English
Weight
850 KB
Volume
28
Category
Article
ISSN
0730-725X

No coin nor oath required. For personal study only.

✦ Synopsis


Purpose:

To develop a method for estimating metabolite concentrations using phased-array coils and sensitivity-encoded (sense) magnetic resonance spectroscopic images (mrsi) of the human brain.

Materials and methods:

The method is based on the phantom replacement technique and uses receive coil sensitivity maps and body-coil loading factors to account for receive b(1) inhomogeneity and variable coil loading, respectively. corrections for cerebrospinal fluid content from the mrsi voxel were also applied, and the total protocol scan time was less than 15 min. the method was applied to 10 normal human volunteers using a multislice 2d-mrsi sequence at 3 t, and seven different brain regions were quantified.

Results:

N-acetyl aspartate (naa) concentrations varied from 9.7 to 14.7 mm, creatine (cr) varied from 6.6 to 10.6 mm and choline (cho) varied from 1.6 to 3.0 mm, in good general agreement with prior literature values.

Conclusions:

Quantitative sense-mrsi of the human brain is routinely possible using an adapted phantom-replacement technique. the method may also be applied to other mrsi techniques, including conventional phase encoding, with phased-array receiver coils, provided that coil sensitivity profiles can be measured.


πŸ“œ SIMILAR VOLUMES


Robust analysis of short echo time 1H MR
✍ X. P. Zhu; K. Young; A. Ebel; B. J. Soher; L. Kaiser; G. Matson; W. M. Weiner; N πŸ“‚ Article πŸ“… 2006 πŸ› John Wiley and Sons 🌐 English βš– 225 KB

## Abstract Short echo time proton MR Spectroscopic Imaging (MRSI) suffers from low signal‐to‐noise ratio (SNR), limiting accuracy to estimate metabolite intensities. A method to coherently sum spectra in a region of interest of the human brain by appropriate peak alignment was developed to yield a

In vivo quantitative proton MRSI study o
✍ Alena HorskΓ‘; Walter E. Kaufmann; Larry J. Brant; Sakkubai Naidu; James C. Harri πŸ“‚ Article πŸ“… 2002 πŸ› John Wiley and Sons 🌐 English βš– 360 KB

## Abstract ## Purpose To quantify regional variations in metabolite levels in the developing brain using quantitative proton MR spectroscopic imaging (MRSI). ## Materials and Methods Fifteen healthy subjects three to 19 years old were examined by in vivo multislice proton MRSI. Concentrations o

Quantitative spectroscopic imaging of th
✍ Jullie W. Pan; Donald B. Twieg; Hoby P. Hetherington πŸ“‚ Article πŸ“… 1998 πŸ› John Wiley and Sons 🌐 English βš– 722 KB

A method to provide B1 correction and cerebrospinal fluid (CSF) referencing is developed and applied to spectroscopic imaging of the human brain at 4.1 T using a volume head coil. The B1 image allows rapid determination of the spatially dependent B1 that is then used to compensate for the B1 sensiti