Quantitative spectroscopic imaging of the human brain
β Scribed by Jullie W. Pan; Donald B. Twieg; Hoby P. Hetherington
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 722 KB
- Volume
- 40
- Category
- Article
- ISSN
- 0740-3194
No coin nor oath required. For personal study only.
β¦ Synopsis
A method to provide B1 correction and cerebrospinal fluid (CSF) referencing is developed and applied to spectroscopic imaging of the human brain at 4.1 T using a volume head coil. The B1 image allows rapid determination of the spatially dependent B1 that is then used to compensate for the B1 sensitivity of the spectroscopic sequence. The reference signal is acquired from CSF located in a lateral ventricular position using a point-resolved echo spectroscopy (PRESS) acquisition. The CSF spectrum is also corrected for B1 dependence. Together with T2 and T1 corrections, this method is used to provide quantitative values of N-acetylaspartate (NAA), creatine (Cr), and choline (Ch). The metabolite concentrations obtained from a spectroscopic imaging slice through the ventricles in seven normal controls are in good agreement with previously published literature values. This method is applied in a patient with secondary progressive multiple sclerosis, showing separate areas of abnormalities in both NAA and Cr.
π SIMILAR VOLUMES
## Abstract Quantitative, multislice proton MR spectroscopic imaging (MRSI) was used to investigate regional metabolite levels and ratios in the normal adult human posterior fossa. Six normal volunteers (36 Β± 3 years, five male, one female) were scanned on a 1.5 T scanner using multislice MRSI at l
Previous measurements of the ratio of brain to venous blood alcohol have ranged from 21-100%, depending on the experimental model, pulse sequence, and the concentration reference used. The goal of this study was to evaluate the uptake kinetics and visibility of brain ethanol in comparison to venous
## Abstract Spectroscopic imaging of phosphorus metabolites in the human brain has been carried out with two data acquisition methods: by observation of the free induction decay (FID) signal and by a short spin echo sequence. The resultant spectral images and spatially resolved spectra are compared
One-dimensional spectroscopic imaging of 13 C-4-glutamate turnover is performed in the human brain with a 6 cc nominal voxel resolution at 4T. Data were acquired with an indirect detection approach using a short spin echo single quantum 1 H-13 C heteronuclear editing method and a 7 cm surface coil w