A matrix-assisted laser desorption/ionization-quadrupole ion trap/reΓectron time-of-Γight (MALDI-QIT/reTOF) mass spectrometer design and its operation in both normal and tandem mass spectrometric modes are described. A parabolic reΓectron was found to be capable of providing mass resolution of 5000
Procedures for Tandem Mass Spectrometry on an Ion Trap Storage/Reflectron Time-of-flight Mass Spectrometer
β Scribed by Mark G. Qian; David M. Lubman
- Publisher
- John Wiley and Sons
- Year
- 1996
- Tongue
- English
- Weight
- 835 KB
- Volume
- 10
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
In this work, we demonstrate tandem mass spectrometry on an ion trap storage-reflectron time-of-fight mass spectrometer (IT/reTOFMS). Ion isolation and activation were achieved by resonant excitation using multi-and single-frequency waveforms generated from an analog circuit. Product-ion spectra of small polypeptides are obtained, which are comparable in fragmentation to those acquired on sector or hybrid mass spectrometers. Several important parameters governing the tandem mass spectrometry process, including the activation tickle voltage, type of collision gas, activation period and cooling period after the fragmentation were optimized using leucine-enkephalin as a model. Although the limited energy deposition from collisional activation in our experiments does not allow efficient fragmentation of large singly charged pomptides with m/z higher than 1O00, the problem may be partially solved by taking advantage of fragmenting the multiply charged ions produced from the electrospray ionization source as demonstrated for a synthetic polypeptide of molecular weight 2782. Compared to the singly charged form, the reduced m/z of multiply charged forms experience a greater trapping force as described by the pseudopotential well-depth model. Increased pseudopotential welldepths for multiply charged species permit the use of greater fragmentation energy at lower RF potentials. These conditions facilitate the fragmentation of large polypeptides, yet are suitable for trapping singly charged fragments. These experiments indicate that the high efficiency associated with ion dissociation and fragment-ion collection in the trap and the storage capability for detection of ions using the non-scanning mode of the IT/ reTOF analyzer may provide an alternative means for acquiring sequence-specific information of polypeptides at low picomol levels of sensitivity.
π SIMILAR VOLUMES
In this work a capillary high-performance liquid chromatography/tandem mass spectrometry system has been developed in a quadrupole ion trap/reflectron time-of-flight mass spectrometer. The broadband excitation for isolating a precursor ion is achieved by generating the stored waveform inverse Fourie
Packed-capillary high-performance liquid chromatography (HPLC) was successfully coupled with an ion trap storage/reflectron time-of-flight mass spectrometer (LC/IT/reTOFMS) through an electrospray ionization interface for protein structural elucidation. Using the total-ion storage capabilities of th
A tandem quadrupole ion-storage trap, time-of-flight instrument using matrix-assisted laser desorptionl ionization has been constructed. Desorbed ions are lint trapped in an RF' field and collisionally relaxed prior to time-of-!light mass analysis. So far masses up to 90 kDa, a resolution of up to 7
A tandem reflectron time-of-flight mass spectrometer developed in Glasgow University was used for the investigation of photofragmentation of the molecular ions of the amino acid derivatives: PTH-tryptophan, PTHvaline, and PTH-alanine as well as of cytosine and guanine. The molecular ions were genera
## Mass -selected reagent ion chemical ionization (CI) performed in an ion trap instrument is an efficient tool to investigate gas-phase ion reactivities and therefore to find out new and/or optimized applications for structural analysis. For instance, it was shown that the C 3 H 6 O + . (58 mass