๐”– Bobbio Scriptorium
โœฆ   LIBER   โœฆ

Polymer membrane electrodes: Part II. A potassium ion-selective membrane electrode

โœ Scribed by G. Baum; M. Lynn


Book ID
108305184
Publisher
Elsevier Science
Year
1973
Tongue
English
Weight
522 KB
Volume
65
Category
Article
ISSN
0003-2670

No coin nor oath required. For personal study only.


๐Ÿ“œ SIMILAR VOLUMES


Photo-cured polymers in ion-selective el
โœ T.J. Cardwell; R.W. Cattrall; P.J. Iles; I.C. Hamilton ๐Ÿ“‚ Article ๐Ÿ“… 1988 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 245 KB

The preparation of a potassium-selective electrode based on a photo-cured polymer membrane containing valinomycin is reported. This electrode has similar response characteristics to one based on PVC with the same neutral carrier. It is suitable for use in flow-injection systems because of its fast i

Photocured polymers in ion-selective ele
โœ R.W. Cattrall; P.J. Iles; I.C. Hamilton ๐Ÿ“‚ Article ๐Ÿ“… 1985 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 210 KB

A fast and convenient method is reported for preparing ion-selective electrode membranes based on bisphenol A epoxyacrylate, 1,6-hexanedioldiacrylate and benzophenone photoinitiator. A calcium-selective electrode is used as example; responses are Nemstian in the range 1O-'-lO-5 M with the calcium sa

Micromachined ion-selective electrodes w
โœ M. Knoll; K. Cammann; C. Dumschat; J. Eshold; C. Sundermeier ๐Ÿ“‚ Article ๐Ÿ“… 1994 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 779 KB

We have developed a new method for the integration of ion-sensitive membranes and silicon sensor chips. The ion-sensitive membrane is deposited in pyramidal containments produced on silicon by an anisotropic etching technique. Here we demonstrate the application of this method to the development of

Polymer Membrane Ion-Selective Electrode
โœ Eric Bakker; Philippe Bรผhlmann; Ernรถ Pretsch ๐Ÿ“‚ Article ๐Ÿ“… 1999 ๐Ÿ› John Wiley and Sons ๐ŸŒ English โš– 697 KB

This article reviews recent advances in the ยฎeld of potentiometric solvent polymeric membrane electrodes. These sensors have found widespread applications in a variety of ยฎelds, especially in the area of clinical diagnostics. Emphasis is given on the discussion of the theoretical and practical limit

Photocured polymers in ion-selective ele
โœ J.R. Farrell; P.J. Iles; T. Dimitrakopoulos ๐Ÿ“‚ Article ๐Ÿ“… 1996 ๐Ÿ› Elsevier Science ๐ŸŒ English โš– 378 KB

A photocured sodium ion-selective electrode, based on the ionophore N,N-dibenzyl-N,N'-diphenyl-1,2-phenylenedioxydiacetamide (ETH 157), was developed and evaluated. The robust nature of the photocured membrane made it ideally suited for measurements in flow injection potentiometry. The detection lim