Many zeotropic refrigerant mixtures are being proposed as alternatives to CFCs and HFCFs refrigerants that are being phased out. The main advantage in the use of zeotropic mixtures is the possibility of reduction in entropy generation in the condenser and evaporator by matching the glides of refrige
Performance enhancement of some alternatives to R-502
โ Scribed by Samuel M. Sami; Daniel E. Desjardins
- Publisher
- John Wiley and Sons
- Year
- 2000
- Tongue
- English
- Weight
- 133 KB
- Volume
- 24
- Category
- Article
- ISSN
- 0363-907X
No coin nor oath required. For personal study only.
โฆ Synopsis
The results of an experimental study on the behaviour of some new alternatives to R-502 using heated suction accumulator are presented. The experimental set up was composed of a fully instrumented air}source heat pump with a capacity of 12 000 BTUH and equipped with a heated suction accumulator.
The refrigerant temperatures were varied at the evaporator entrance to simulate various extreme conditions encountered in air}source heat pump applications. The primary parameters observed during the course of this study were mass #ux, heat #ux, quality evaporator and condenser thermal capacities, power consumed and pressure ratios for the azeotropic refrigerant mixtures under investigation.
The test results showed that a heated suction accumulator enhanced the evaporation of more volatile component of ternary azeotropic refrigerant mixtures. Thus, increasing the mixture thermal capacity as well as the COP. Furthermore, experiments have also shown capacity increases of 27 per cent with a heat accumulator over an unheated accumulator at !153C outside air temperatures.