Abstract
A quantitative analysis was undertaken to calibrate the perfusion quantification technique based on tracking the first pass of a bolus of a blood pool contrast agent. A complete simulation of the bolus passage, of the associated changes in the T~2~ and T signals, and of the data processing was performed using the tracer dilution theory, an analytical theory of the MR signal from living tissues and numerical simulations. The noise was excluded in the simulation in order to analyze the ultimate accuracy of the method. It is demonstrated that the relationship between the contrast agent concentration and the associated changes in the transverse relaxation rate shows essentially different forms in studied tissue and in the reference artery. This effect results in systematic deviations of the measured blood flow, blood volume, and the residue function obtained with conventional processing from their true values. The error depends on the microvascular composition, the properties of the contrast agent, and the weights of the various compartments in the total signal. The results show that dynamic susceptibility contrast MRI can reach the goal of absolute perfusion quantification only with additional input from measurements of the microvascular architecture. Alternatively, the method can be used to provide such information if the perfusion is quantified by another modality. Magn Reson Med 46:1113β1122, 2001. Β© 2001 WileyβLiss, Inc.
π SIMILAR VOLUMES
## Abstract ## Purpose To examine the sensitivity of quantitative dynamic contrast enhanced MRI (DCEβMRI) perfusion maps to errors in the various source images and to determine optimal imaging parameters for reducing this sensitivity. ## Materials and Methods A detailed analysis of the precision
In this study, spin-echo and gradient-echo-based perfusion magnetic resonance imaging (MRI) techniques are systematically compared with respect to their application in the human brain. Six healthy subjects were evaluated with both techniques consecutively and injected twice with a gadolinium-based c
## Abstract Measurement of myocardial and brain perfusion when using exogenous contrast agents (CAs) such as gadoliniumβDTPA (GdβDTPA) and MRI is affected by the diffusion of water between compartments. This water exchange may have an impact on signal enhancement, or, equivalently, on the longitudi
## Abstract ## Purpose To evaluate the usefulness of the washβin rate based on dynamic contrastβenhanced (DCE) MRI for the detection and localization of prostate cancer. ## Materials and Methods In 53 patients, the washβin rate was measured in the cancer area and in three normal areas (the perip