## Abstract ## Purpose: To evaluate the diagnostic ability of diffusion‐weighted imaging (DWI) and dynamic contrast‐enhanced imaging (DCEI) in combination with T2‐weighted imaging (T2WI) for the detection of prostate cancer using 3 T magnetic resonance imaging (MRI) with a phased‐array body coil.
Wash-in rate on the basis of dynamic contrast-enhanced MRI: Usefulness for prostate cancer detection and localization
✍ Scribed by Jeong Kon Kim; Seong Sook Hong; Young Jun Choi; Seong Ho Park; Hanjong Ahn; Choung-Soo Kim; Kyoung-Sik Cho
- Publisher
- John Wiley and Sons
- Year
- 2005
- Tongue
- English
- Weight
- 233 KB
- Volume
- 22
- Category
- Article
- ISSN
- 1053-1807
No coin nor oath required. For personal study only.
✦ Synopsis
Abstract
Purpose
To evaluate the usefulness of the wash‐in rate based on dynamic contrast‐enhanced (DCE) MRI for the detection and localization of prostate cancer.
Materials and Methods
In 53 patients, the wash‐in rate was measured in the cancer area and in three normal areas (the peripheral zone, inner portion of the transitional zone, and outer portion of the transitional zone). On the basis of these data, parametric imaging was generated and then its accuracy for cancer detection and location was evaluated compared to that of T2‐weighted imaging without the use of an endorectal coil. For that purpose the entire prostate was divided into 18 segments.
Results
The wash‐in rate value was greater in cancer tissue (9.2/second) than in three normal tissues (3.3/second, 6.7/second, and 3.2/second, respectively; P < 0.001). The sensitivity and specificity were greater on parametric imaging of the wash‐in rate compared to T2‐weighted imaging in the entire prostate (96% and 82% vs. 65% and 60%, respectively) and the peripheral zone (96% and 97% vs. 75% and 53%; P < 0.05). In the transitional zone, the sensitivity was greater on parametric imaging (96%) than on T2‐weighted imaging (45%; P = 0.016), but the specificity was similar (51% vs. 73%; P = 0.102).
Conclusion
The wash‐in rate based on DCE‐MRI is a useful parameter for prostate cancer detection and localization. J. Magn. Reson. Imaging 2005. © 2005 Wiley‐Liss, Inc.
📜 SIMILAR VOLUMES
## Abstract ## Purpose To investigate the effectiveness of a polydisulfide‐based biodegradable macromolecular contrast agent, (Gd‐DTPA)‐cystamine copolymers (GDCC), in assessing the efficacy of indocyanine green‐enhanced photothermal cancer therapy using dynamic contrast‐enhanced magnetic resonanc
Gd-DTPA kinetics in arterial blood was investigated by dynamic MRI in 47 patients with malignant and benign mammary tumors. Signal enhancement was monitored for 10 min after the beginning of a 1-min infusion of 0.1 mmol/kg Gd-DTPA. Kinetics in blood was biexponential with median half-lives of 21 sec