On the origin of the abundance distribution of apomyoglobin multiply charged ions in electrospray mass spectrometry
β Scribed by Cecile Meunier; Marc Jamin; Edwin De Pauw
- Publisher
- John Wiley and Sons
- Year
- 1998
- Tongue
- English
- Weight
- 178 KB
- Volume
- 12
- Category
- Article
- ISSN
- 0951-4198
No coin nor oath required. For personal study only.
β¦ Synopsis
The abundance distribution of multiply charged ions produced during the electrospray process is thought to depend on the initial conformational state of the analyte in solution and on solution chemistry, but with some proteins, including apomyoglobin, the correlation between solution and mass spectrometry data is unclear. In this study, we compare our results obtained by mass spectrometry with available data describing conformations and average number of charges of apomyoglobin in solution. A good correlation between average number of charges in solution and in the mass spectrum is only found for the pH 4.2 solution. We propose that the discrepancies between solution and electrospray ionization mass spectrometry observed with apomyoglobin under other solution conditions can be mainly explained by (1) a preferential fragmentation of the highly charged ions in the source and (2) a variation of pH in the droplets during the electrospray process.
π SIMILAR VOLUMES
The mass spectrometry (MS) behaviour of ten commercially available penicillins has been studied by means of electrospray and multiple-stage MS/MS experiments performed using an ion trap instrument. For all the examined compounds negative ions are produced under ESI conditions, with a yield two or th
The number of publications documenting the utility of electrospray ionization (ESI) Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) for the analysis of biological molecules has increased in geometric proportion spanning diverse areas of research. Currently, we are investigatin
Phosphorylation is a post-translational modification of proteins important for signal transduction and enzyme activity. Electrospray ionization mass spectrometry (ESI-MS) has served as an important tool in the identification of phosphorylation sites in many proteins. Enzymatic digestion and peptide
The sensitivity of all ion trap mass spectrometry (ITMS) methods is dependent on the trapping efficiency of the instrument. For ITMS instruments utilizing external ion sources, such as laser desorption, trapping efficiency is known to depend on the phase and amplitude of the radio frequency (RF) pot